Chassis Mount Resistors
-
Wirewound resistor Ohmite 825F100 designed for thermal management and resistance stability in circuits
Ohmite 89 Series Metal-Mite Aluminum Housed Axial Terminal Wirewound Resistors The 89 Series Metal-Mite resistors are high-performance, molded-construction, metal-housed wirewound resistors designed for demanding applications. Their aluminum housing provides excellent heat-sinking capabilities, allowing for chassis mounting and improved thermal management, leading to high stability (0.5% R). These resistors offer a high power-to-size ratio and are well-suited for withstanding
-
High stability Ohmite 825F7R5 resistor with solder coated terminals and chassis mounting capability
Product OverviewThe 89 Series Metal-Mite is a high-performance, aluminum-housed axial terminal wirewound resistor designed for demanding applications. These resistors offer a high power-to-size ratio, excellent stability (0.5% R), and robust construction suitable for vibration, shock, and harsh environments. The metal housing provides chassis mounting capability and effective heat sinking, ensuring high stability during operation.Product AttributesBrand: OhmiteSeries: 89
-
Precision base mounted current shunt muRata 3020-01106-0 with manganin sensing element and 750V isolation
Murata Power Solutions 50mV and 100mV Base-mounted Current Shunts Murata Power Solutions' 50mV and 100mV base-mounted current shunts are precision instruments designed for measuring DC currents ranging from 5A to 1200A. Featuring an accuracy of 0.25%, these shunts connect directly to MPS's DCA5-20PC Series of DC ammeters. They offer straightforward installation with threaded studs for load circuit connection and mV Kelvin-outputs for ammeter input. The shunts are built with a
-
base mounted current shunt muRata 3020-01108-0 with 750V isolation and wide operating temperature
Murata Power Solutions 50mV and 100mV Base-mounted Current Shunts Murata Power Solutions' 50mV and 100mV base-mounted current shunts are designed for precise DC current measurement, ranging from 5A to 1200A. These shunts offer +/-0.25% accuracy and connect directly to MPS's DCA5-20PC Series of DC ammeters. Featuring a rugged phenolic base for 750V isolation and a stable manganin sensing element, they provide a wide operating temperature range of -40 to +60C. Installation is
-
Base mounted current shunt muRata 3020-01101-0 featuring brass terminals and manganin sensing element
Murata Power Solutions 50mV and 100mV Base-mounted Current ShuntsMurata Power Solutions' 50mV and 100mV base-mounted current shunts are precision instruments designed for measuring DC currents ranging from 5A to 1200A. With an accuracy of +/-0.25%, these shunts connect directly to Murata's DCA5-20PC Series DC ammeters. They feature a rugged phenolic base for 750V isolation and a highly stable manganin sensing element, providing a wide operating temperature range of -40 to
-
Current shunt base mounted muRata 3020-01104-0 featuring manganin sensing element and 750V isolation for precise dc current
Murata Power Solutions 50mV and 100mV Base-mounted Current ShuntsMurata Power Solutions' 50mV and 100mV base-mounted current shunts are designed for precise DC current measurement ranging from 5A to 1200A. Featuring +/-0.25% accuracy, these shunts connect directly to MPS's DCA5-20PC Series DC ammeters for straightforward installation. They offer a rugged phenolic base with 750V isolation and a stable manganin sensing element providing a wide operating temperature range of -40
-
Current measurement shunt muRata 3020-01107-0 base mounted 10A 100mV with phenolic base and brass terminals
Murata Power Solutions DMS Accessories: 50mV and 100mV Base-mounted Current Shunts Murata Power Solutions' 50mV and 100mV base-mounted current shunts are designed for accurate DC current measurement, ranging from 5A to 1200A. These precision shunts, featuring +/-0.25% accuracy, are ideal for direct connection with MPS's DCA5-20PC Series DC ammeters. Installation is simplified by connecting the load circuit to the shunt's threaded studs and the shunt's mV Kelvin outputs to the
-
base mounted current shunt muRata 3020-01100-0 suitable for dc current measurement up to 1200 amperes
Murata Power Solutions 50mV and 100mV Base-mounted Current ShuntsMurata Power Solutions' 50mV and 100mV base-mounted current shunts are designed for accurate DC current measurement ranging from 5A to 1200A. These precision shunts, featuring +/-0.25% accuracy, connect directly to MPS's DCA5-20PC Series of DC ammeters. They offer straightforward installation by connecting the load circuit to the shunt's threaded studs and the shunt's mV Kelvin-outputs to the ammeter's input
-
Compact and precise DC current shunt muRata 3020-01103-0 suitable for direct metal surface mounting
Product OverviewMurata Power Solutions' 50mV and 100mV base-mounted current shunts are designed for precise DC current measurement ranging from 5A to 1200A. These shunts offer +/-0.25% accuracy and connect directly to MPS's DCA5-20PC Series DC ammeters. Featuring a rugged phenolic base for 750V isolation and a stable manganin sensing element, they operate reliably within a -40 to +60C temperature range. Installation is simplified by connecting the load circuit to threaded
-
Current measurement shunt muRata 3020-01096-0 featuring manganin sensing element and phenolic base for stable operation
Murata Power Solutions 50mV and 100mV Base-Mounted Current ShuntsThese precision current shunts are designed for measuring DC currents ranging from 5A to 1200A. They offer 0.25% accuracy and connect directly to Murata Power Solutions' DCA5-20PC Series DC ammeters. Installation is simplified by connecting the load circuit to the shunt's threaded studs and the shunt's mV Kelvin-outputs to the ammeter's input terminals. Featuring a rugged phenolic base for 750V isolation and a
-
Precision dc current shunt muRata 3020-01097-0 base mounted with 50mV output and rugged brass terminals
Murata Power Solutions 50mV and 100mV Base-mounted Current Shunts Murata Power Solutions' 50mV and 100mV base-mounted current shunts are precision devices designed for measuring DC currents ranging from 5A to 1200A. With an accuracy of +/-0.25%, these shunts connect directly to MPS's DCA5-20PC Series of DC ammeters. They feature a rugged phenolic base offering 750V isolation and a highly stable manganin sensing element, enabling a wide operating temperature range of -40 to
-
Durable 20A 50mV Current Shunt Murata 3020-01098-0 with Phenolic Base and Kelvin Output Connections
Murata Power Solutions 50mV and 100mV Base-mounted Current ShuntsMurata Power Solutions' 50mV and 100mV base-mounted current shunts are designed for accurate DC current measurement ranging from 5A to 1200A. These precision shunts, featuring +/-0.25% accuracy, are ideal for direct connection with MPS's DCA5-20PC Series of DC ammeters. Installation is simplified by connecting the load circuit to the shunt's threaded studs and the shunt's mV Kelvin outputs to the ammeter's input