Product Overview
The Vishay Sfernice LPS 600 is a high-power resistor designed for mounting onto a heatsink. Utilizing thick film technology, it offers a robust solution for demanding applications requiring efficient heat dissipation. Key advantages include high power handling (600 W at 85 C bottom case temperature), a wide resistance range, non-inductive design, and easy mounting. Its low thermal radiation of the case and compliance with NF-EN45545-2 requirement #26 make it suitable for various industrial and safety-critical applications.
Product Attributes
- Brand: Vishay Sfernice
- Technology: Thick Film
- Flammability: UL 94 V-0
- Certifications: Compliant with requirement #26 of NF-EN45545-2
- Material categorization: Refer to www.vishay.com/doc?99912
- 3D Models: Available
Technical Specifications
| Model | Resistance Range () | Rated Power P85C (W) | Limiting Element Voltage UL (V) | Tolerance (%) | Temperature Coefficient (ppm/C) | Critical Resistance () | Dimensions (mm) | Weight (g) |
| LPS 600 | 0.3 to 900K | 600 | 5K | 1, 2, 5, 10 | 150, 300, 500 | 41.66K | 57 x 34 x 60 (LxWxH) | 83 10% |
| Specification | Value |
| Temperature Range | -55 C to +155 C |
| Climatic Category | 55 / 155 / 56 |
| Power Rating and Thermal Resistance | 600 W at +85 C bottom case temperature |
| RTH (j-c) | 0.112 C/W |
| Temperature Coefficient (R 1 ) | 500 ppm/C |
| Temperature Coefficient (1 < R 10 ) | 300 ppm/C |
| Temperature Coefficient (10 < R) | 150 ppm/C |
| Dielectric Strength (IEC 60115-1) | 7 kVRMS or 12 kVRMS |
| Lightning Test (IEC 60000-4-5) | Until 12 kV (1.2/50 s) |
| Insulation Resistance | 104 M |
| Inductance | 0.1 H |
| Partial Discharge (LPS 600 D only) | 100 pC/7 kV / 10 pC/5 kV |
| Substrate | Alumina |
| End Connections | Screws M4 |
| Tightening Torque (Connections) | 2 Nm |
| Tightening Torque (Heatsink) | 2 Nm |
| Maximum Torque | 2.5 Nm |
| Performance Test | Conditions | Requirements |
| Momentary Overload | IEC 60115-1, 2 x Pr / 10 s | Umax. UL = 5000 V, (0.25 % + 0.05 ) |
| Rapid Temperature Change | IEC 60115-1/IEC 60068-2-14 Test Na, 50 cycles -55 C to +155 C | (0.5 % + 0.05 ) |
| Load Life | IEC 60115-1, 1000 h (90/30) Pr at 85 C | (0.5 % + 0.05 ) |
| Humidity (Steady State) | IEC 60115-1, 56 days RH 95 % / 40 C | (0.5 % + 0.05 ) |
| Vibration | MIL STD 202 method 204 cond. D (10 g; 5/500 Hz) | (0.25 % + 0.05 ) |
| Climatic Sequence | IEC 60115-1 (55 / 155 / 56) | (1 % + 0.05 ) |