Vishay Dale IHLP Commercial Inductors, Low DCR Series
The Vishay Dale IHLP Commercial Inductors, Low DCR Series are designed for excellent DC/DC energy storage up to 1 MHz to 2 MHz and filter inductor applications up to SRF. These shielded construction inductors offer an operating temperature range of -55 C to +125 C, lowest DCR/H in their package size, and the ability to handle high transient current spikes without saturation. Their ultra-low buzz noise is attributed to their composite construction. These inductors are ideal for PDA/notebook/desktop/server applications, high current POL converters, low profile, high current power supplies, battery-powered devices, DC/DC converters in distributed power systems, and DC/DC converters for Field Programmable Gate Arrays (FPGAs).
Product Attributes
- Brand: Vishay Dale
- Series: IHLP Commercial Inductors, Low DCR Series
- Construction: Shielded
- Material: Composite
- Certifications: RoHS (Pb)-Free Standard
Technical Specifications
| Inductance (H) | Inductance Tolerance | DCR Typ. 25 C (m) | DCR Max. 25 C (m) | Heat Rating Current DC Typ. (A) (1) | Saturation Current DC Typ. (A) (2) | SRF Typ. (MHz) |
| 0.22 | 20 % | 1.51 | 1.62 | 36.0 | 24.0 | 151 |
| 0.33 | 20 % | 2.22 | 2.38 | 27.0 | 18.0 | 101 |
| 0.47 | 20 % | 2.54 | 2.72 | 24.0 | 18.0 | 69 |
| 0.68 | 20 % | 3.73 | 3.99 | 20.0 | 15.2 | 59 |
| 0.82 | 20 % | 4.55 | 4.87 | 18.5 | 15.0 | 53 |
| 1.0 | 20 % | 6.07 | 6.49 | 16.0 | 14.8 | 51 |
| 1.5 | 20 % | 8.29 | 9.94 | 12.5 | 11.3 | 35 |
| 2.2 | 20 % | 13.70 | 14.70 | 10.4 | 10.4 | 30 |
| 4.7 | 20 % | 26.70 | 28.60 | 7.6 | 5.4 | 21 |
| 6.8 | 20 % | 35.30 | 37.80 | 6.5 | 5.0 | 17 |
| 8.2 | 20 % | 43.60 | 46.70 | 5.9 | 4.2 | 16 |
| 10 | 20 % | 51.50 | 55.10 | 5.3 | 3.8 | 12 |
| 15 | 20 % | 79.70 | 85.30 | 4.3 | 3.8 | 11 |
| 22 | 20 % | 123.0 | 132.0 | 3.6 | 2.8 | 7.7 |
| 33 | 20 % | 166.0 | 177.0 | 3.1 | 2.1 | 5.6 |
Notes:
- All test data is referenced to 25 C ambient.
- Operating temperature range: -55 C to +125 C.
- The part temperature (ambient + temp. rise) should not exceed 125 C under worst-case operating conditions.
- Rated operating voltage (across inductor) = 50 V.
- (1) DC current (A) that will cause an approximate T of 40 C.
- (2) DC current (A) that will cause L0 to drop approximately 20 %.