Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Multilayer Ferrite Beads TE Connectivity BMC1HY0030AN for EMI Protection in Telecommunication Devices factory
<
quality Multilayer Ferrite Beads TE Connectivity BMC1HY0030AN for EMI Protection in Telecommunication Devices factory
>
Specifications
Current Rating:
300mA
Number of Circuits:
1
DC Resistance(DCR):
300mΩ
Tolerance:
±25%
Impedance @ Frequency:
30Ω@100MHz
Mfr. Part #:
BMC1HY0030AN
Package:
0201
Key Attributes
Model Number: BMC1HY0030AN
Product Description

Product Description

Multilayer Ferrite Beads designed for effective EMI protection, offering low DC resistance and high soldering heat resistance. Available in multiple size options, these beads are ideal for various electronic applications including cellular phones, computers and peripheral equipment, automation controls, sensors, VCRs, televisions, and pagers. They are particularly useful in circuits where a stable ground is unavailable. The BMC Series features a monolithic inorganic material construction that minimizes electromagnetic interference.

Product Attributes

  • Brand: TE Connectivity (implied by www.te.com/help)
  • Series: BMC Series
  • Material: Monolithic inorganic material

Technical Specifications

SeriesPackage SizePart No.Impedance ()ToleranceTest Freq. (MHz)DCR ()max.Rated Current (mA)max. at 85Application Type
BMC0201 ANBMC1HY0010AN1025%1000.10500General Signal Line Use
BMC0201 ANBMC1HY0030AN3025%1000.30300General Signal Line Use
BMC0201 ANBMC1HY0033AN3325%1000.30300General Signal Line Use
BMC0201 ANBMC1HY0040AN4025%1000.30300General Signal Line Use
BMC0201 ANBMC1HY0050AN5025%1000.30300General Signal Line Use
BMC0201 ANBMC1HY0060AN6025%1000.35300General Signal Line Use
BMC0201 ANBMC1HY0070AN7025%1000.35300General Signal Line Use
BMC0201 ANBMC1HY0100AN10025%1000.40200General Signal Line Use
BMC0201 ANBMC1HY0120AN12025%1000.45200General Signal Line Use
BMC0201 ANBMC1HY0150AN15025%1000.50200General Signal Line Use
BMC0201 ANBMC1HY0220AN22025%1000.75200General Signal Line Use
BMC0201 ANBMC1HY0300AN30025%1000.90150General Signal Line Use
BMC0402 ANBMC1EY0010AN1025%1000.05500General Signal Line Use
BMC0402 ANBMC1EY0030AN3025%1000.20300General Signal Line Use
BMC0402 ANBMC1EY0040AN4025%1000.20300General Signal Line Use
BMC0402 ANBMC1EY0060AN6025%1000.40200General Signal Line Use
BMC0402 ANBMC1EY0068AN6825%1000.15500General Signal Line Use
BMC0402 ANBMC1EY0070AN7025%1000.40200General Signal Line Use
BMC0402 ANBMC1EY0080AN8025%1000.40200General Signal Line Use
BMC0402 ANBMC1EY0100AN10025%1000.45200General Signal Line Use
BMC0402 ANBMC1EY0120AN12025%1000.50200General Signal Line Use
BMC0402 ANBMC1EY0150AN15025%1000.60200General Signal Line Use
BMC0402 ANBMC1EY0180AN18025%1000.65100General Signal Line Use
BMC0402 ANBMC1EY0220AN22025%1000.28700General Signal Line Use
BMC0402 ANBMC1EY0240AN24025%1000.30500General Signal Line Use
BMC0402 ANBMC1EY0300AN30025%1000.75100General Signal Line Use
BMC0402 ANBMC1EY0330AN33025%1000.75100General Signal Line Use
BMC0402 ANBMC1EY0430AN43025%1000.50350General Signal Line Use
BMC0402 ANBMC1EY0470AN47025%1000.90100General Signal Line Use
BMC0402 ANBMC1EY0500AN50025%1001.00100General Signal Line Use
BMC0402 ANBMC1EY0600AN60025%1001.1050General Signal Line Use
BMC0402 ANBMC1EY1000AN100025%1001.5050General Signal Line Use
BMC0603 ANBMC1JY0019AN1925%1000.10400General Signal Line Use
BMC0603 ANBMC1JY0031AN3125%1000.10400General Signal Line Use
BMC0603 ANBMC1JY0052AN5225%1000.15400General Signal Line Use
BMC0603 ANBMC1JY0060AN6025%1000.15400General Signal Line Use
BMC0603 ANBMC1JY0075AN7525%1000.15400General Signal Line Use
BMC0603 ANBMC1JY0080AN8025%1000.15400General Signal Line Use
BMC0603 ANBMC1JY0100AN10025%1000.15400General Signal Line Use
BMC0603 ANBMC1JY0120AN12025%1000.15400General Signal Line Use
BMC0603 ANBMC1JY0150AN15025%1000.15400General Signal Line Use
BMC0603 ANBMC1JY0180AN18025%1000.20400General Signal Line Use
BMC0603 ANBMC1JY0200AN20025%1000.20400General Signal Line Use
BMC0603 ANBMC1JY0220AN22025%1000.20400General Signal Line Use
BMC0603 ANBMC1JY0240AN24025%1000.17500General Signal Line Use
BMC0603 ANBMC1JY0300AN30025%1000.2600General Signal Line Use
BMC0603 ANBMC1JY0400AN40025%1000.30400General Signal Line Use
BMC0603 ANBMC1JY0420AN42025%1000.30400General Signal Line Use
BMC0603 ANBMC1JY0450AN45025%1000.30400General Signal Line Use
BMC0603 ANBMC1JY0600AN60025%1000.35400General Signal Line Use
BMC0603 ANBMC1JY0750AN75025%1000.35400General Signal Line Use
BMC0603 ANBMC1JY1000AN100025%1000.55300General Signal Line Use
BMC0603 ANBMC1JY1000AN1100025%1000.25800General Signal Line Use
BMC0603 ANBMC1JY1500AN150025%1000.60200General Signal Line Use
BMC0805 ANBMC2AY0017AN1725%1000.10300General Signal Line Use
BMC0805 ANBMC2AY0026AN2625%1000.10300General Signal Line Use
BMC0805 ANBMC2AY0030AN3025%1000.10300General Signal Line Use
BMC0805 ANBMC2AY0031AN3125%1000.10300General Signal Line Use
BMC0805 ANBMC2AY0052AN5225%1000.15300General Signal Line Use
BMC0805 ANBMC2AY0060AN6025%1000.15300General Signal Line Use
BMC0805 ANBMC2AY0080AN8025%1000.15300General Signal Line Use
BMC0805 ANBMC2AY0100AN10025%1000.20300General Signal Line Use
BMC0805 ANBMC2AY0120AN12025%1000.20300General Signal Line Use
BMC0805 ANBMC2AY0150AN15025%1000.20300General Signal Line Use
BMC0805 ANBMC2AY0220AN22025%1000.25300General Signal Line Use
BMC0805 ANBMC2AY0300AN30025%1000.25300General Signal Line Use
BMC0805 ANBMC2AY0400AN40025%1000.30300General Signal Line Use
BMC0805 ANBMC2AY0470AN47025%1000.18700General Signal Line Use
BMC0805 ANBMC2AY0530AN53025%1000.35300General Signal Line Use
BMC0805 ANBMC2AY0600AN60025%1000.35300General Signal Line Use
BMC0805 ANBMC2AY1000AN100025%1000.45300General Signal Line Use
BMC0805 ANBMC2AY1500AN150025%1000.70300General Signal Line Use
BMC1204 ANBMC2CY0019AN1925%1000.10800General Signal Line Use
BMC1204 ANBMC2CY0026AN2625%1000.10800General Signal Line Use
BMC1204 ANBMC2CY0031AN3125%1000.10800General Signal Line Use
BMC1204 ANBMC2CY0052AN5225%1000.15800General Signal Line Use
BMC1204 ANBMC2CY0060AN6025%1000.15500General Signal Line Use
BMC1204 ANBMC2CY0070AN7025%1000.15500General Signal Line Use
BMC1204 ANBMC2CY0100AN10025%1000.20450General Signal Line Use
BMC1204 ANBMC2CY0120AN12025%1000.20450General Signal Line Use
BMC1204 ANBMC2CY0150AN15025%1000.20450General Signal Line Use
BMC1204 ANBMC2CY0220AN22025%1000.20350General Signal Line Use
BMC1204 ANBMC2CY0300AN30025%1000.20350General Signal Line Use
BMC1204 ANBMC2CY0400AN40025%1000.25350General Signal Line Use
BMC1204 ANBMC2CY0600AN60025%1000.25350General Signal Line Use
BMC1204 ANBMC2CY0750AN75025%1000.30350General Signal Line Use
BMC1204 ANBMC2CY0800AN80025%1000.30350General Signal Line Use
BMC1204 ANBMC2CY1000AN100025%1000.35350General Signal Line Use
BMC1204 ANBMC2CY1200AN120025%1000.35350General Signal Line Use
BMC1210 ANBMC2EY0031AN3125%1000.10500General Signal Line Use
BMC1210 ANBMC2EY0052AN5225%1000.30400General Signal Line Use
BMC1210 ANBMC2EY0060AN6025%1000.30400General Signal Line Use
BMC0402 KNBMC1EY0220KN22025%1000.80100Frequency Higher Than A Use
BMC0402 KNBMC1EY0300KN30025%1000.85100Frequency Higher Than A Use
BMC0603 KNBMC1JY1000KN100025%1000.85100Frequency Higher Than A Use
BMC0603 KNBMC1JY1200KN120025%1000.85100Frequency Higher Than A Use
BMC0603 KNBMC1JY1500KN150025%1000.90100Frequency Higher Than A Use
BMC0603 KNBMC1JY1800KN180025%1001.00100Frequency Higher Than A Use
BMC0603 KNBMC1JY2000KN200025%1001.00100Frequency Higher Than A Use
BMC0603 KNBMC1JY2500KN250025%1001.0050Frequency Higher Than A Use
BMC0805 KNBMC2AY0080KN8025%1000.30300Frequency Higher Than A Use
BMC0805 KNBMC2AY0600KN60025%1000.35200Frequency Higher Than A Use
BMC0805 KNBMC2AY1000KN100025%1000.40200Frequency Higher Than A Use
BMC0805 KNBMC2AY1200KN120025%1000.40200Frequency Higher Than A Use
BMC0805 KNBMC2AY1500KN150025%1000.45200Frequency Higher Than A Use
BMC0805 KNBMC2AY2000KN200025%1000.60200Frequency Higher Than A Use
BMC0805 KNBMC2AY2200KN220025%1000.60200Frequency Higher Than A Use
BMC0805 KNBMC2AY2500KN250025%1000.70200Frequency Higher Than A Use
BMC0805 KNBMC2AY2700KN270025%1000.70200Frequency Higher Than A Use
BMC0402 AGBMC1EY0010AG1025%1000.032000Medium Current Line Use
BMC0402 AGBMC1EY0030AG3025%1000.033000Medium Current Line Use
BMC0402 AGBMC1EY0060AG6025%1000.0751500Medium Current Line Use
BMC0402 AGBMC1EY0070AG7025%1000.091200Medium Current Line Use
BMC0402 AGBMC1EY0100AG10025%1000.091200Medium Current Line Use
BMC0402 AGBMC1EY0120AG12025%1000.0751500Medium Current Line Use
BMC0402 AGBMC1EY0220AG22025%1000.201000Medium Current Line Use
BMC0603 AGBMC1JY0022AG2225%1000.043000Medium Current Line Use
BMC0603 AGBMC1JY0030AG3025%1000.043000Medium Current Line Use
BMC0603 AGBMC1JY0033AG3325%1000.0253000Medium Current Line Use
BMC0603 AGBMC1JY0047AG4725%1000.043000Medium Current Line Use
BMC0603 AGBMC1JY0060AG6025%1000.043000Medium Current Line Use
BMC0603 AGBMC1JY0062AG6225%1000.043000Medium Current Line Use
BMC0603 AGBMC1JY0100AG10025%1000.053000Medium Current Line Use
BMC0603 AGBMC1JY0120AG12025%1000.052000Medium Current Line Use
BMC0603 AGBMC1JY0180AG18025%1000.082000Medium Current Line Use
BMC0603 AGBMC1JY0220AG22025%1000.082000Medium Current Line Use
BMC0603 AGBMC1JY0300AG30025%1000.152000Medium Current Line Use
BMC0603 AGBMC1JY0470AG47025%1000.151500Medium Current Line Use
BMC0603 AGBMC1JY0600AG60025%1000.301000Medium Current Line Use
BMC0603 AGBMC1JY0750AG75025%1000.301000Medium Current Line Use
BMC0603 AGBMC1JY1000AG100025%1000.251000Medium Current Line Use
BMC0805 AGBMC2AY0011AG1125%1000.033000Medium Current Line Use
BMC0805 AGBMC2AY0017AG1725%1000.033000Medium Current Line Use
BMC0805 AGBMC2AY0030AG3025%1000.053000Medium Current Line Use
BMC0805 AGBMC2AY0031AG3125%1000.033000Medium Current Line Use
BMC0805 AGBMC2AY0039AG3925%1000.033000Medium Current Line Use
BMC0805 AGBMC2AY0040AG4025%1000.033000Medium Current Line Use
BMC0805 AGBMC2AY0047AG4725%1000.033000Medium Current Line Use
BMC0805 AGBMC2AY0050AG5025%1000.033000Medium Current Line Use
BMC0805 AGBMC2AY0052AG5225%1000.033000Medium Current Line Use
BMC0805 AGBMC2AY0060AG6025%1000.043000Medium Current Line Use
BMC0805 AGBMC2AY0080AG8025%1000.043000Medium Current Line Use
BMC0805 AGBMC2AY0100AG10025%1000.043000Medium Current Line Use
BMC0805 AGBMC2AY0120AG12025%1000.053000Medium Current Line Use
BMC0805 AGBMC2AY0180AG18025%1000.053000Medium Current Line Use
BMC0805 AGBMC2AY0220AG22025%1000.053000Medium Current Line Use
BMC0805 AGBMC2AY0300AG30025%1000.053000Medium Current Line Use
BMC0805 AGBMC2AY0330AG33025%1000.053000Medium Current Line Use
BMC0805 AGBMC2AY0470AG47025%1000.102000Medium Current Line Use
BMC0805 AGBMC2AY0600AG60025%1000.102000Medium Current Line Use
BMC0805 AGBMC2AY1000AG100025%1000.301000Medium Current Line Use
BMC0805 AGBMC2AY1500AG150025%1000.301000Medium Current Line Use
BMC0402 BNBMC1EY0470BN47025%1001.00100High Speed Signal Line Use
BMC0402 BNBMC1EY0600BN60025%1001.5050High Speed Signal Line Use
BMC0805 BNBMC2AY1500BN150025%1000.35200High Speed Signal Line Use
BMC0805 BNBMC2AY1800BN180025%1000.40200High Speed Signal Line Use
BMC0805 BNBMC2AY2000BN200025%1000.40200High Speed Signal Line Use
BMC0805 BNBMC2AY2200BN220025%1000.50200High Speed Signal Line Use
BMC0805 BNBMC2AY2500BN250025%1000.60200High Speed Signal Line Use
BMC0805 BNBMC2AY2700BN270025%1000.60200High Speed Signal Line Use

2306061213_TE-Connectivity-BMC1HY0030AN_C5846149.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max