Product Overview
The SUMIDA TYPE PFC2225B is a power factor correction inductor designed for various electronic applications. It offers reliable performance with specified inductance, inductance balance, DC resistance, and current handling capabilities. This product adheres to RoHS compliance.
Product Attributes
- Brand: SUMIDA
- Model: PFC2225B
- Certifications: RoHS
Technical Specifications
| Part Number | Stamp | Inductance (mH) (1-2) or (4-3) [MIN.] | Inductance Balance (H) [MAX.] | D.C.R. (m) [at 20] (1-2) or (4-3) [MAX.] | Current (Arms) (50Hz/60Hz) (1-4) | SUMIDA CODE |
|---|---|---|---|---|---|---|
| PFC2225BNP-451 | 451 | 0.45 | 30 | 8.5 | 10.0 | -0015 |
| PFC2225BNP-81 | 801 | 0.8 | 50 | 12.5 | 8.0 | -0016 |
| PFC2225BNP-152 | 152 | 1.5 | 80 | 26.0 | 5.0 | -0017 |
| PFC2225BNP-42 | 402 | 4.0 | 100 | 54.0 | 4.0 | -0018 |
| PFC2225BNP-52 | 502 | 5.0 | 150 | 81.0 | 3.0 | -0019 |
| PFC2225BNP-72 | 702 | 7.0 | 200 | 135 | 2.5 | -0020 |
| PFC2225BNP-52B | 502B | 5.0 | 150 | 61.0 | 3.5 | -0021 |
| PFC2225BNP-72B | 702B | 7.0 | 200 | 70.0 | 3.0 | -0022 |
General Characteristics
| Characteristic | Specification |
|---|---|
| Storage Temperature Range | -4085 |
| Operating Temperature Range | -4085 (Including coils self temperature rise) |
| External Appearance | No external defects can be found in the visual inspection. |
| Resistance to Soldering Heat | No distinguished structure and electric defects should be found after soldering heat (1.50.5mm high bottom of all the terminals are immersed in the melted solder of 2605 for 101 seconds). |
| Insulating Resistance | Over 100M when 500V DC is applied to coil-core. |
| Vibration Test | Inductance deviation is within 3.0% after 1 hour sweeping vibration in each of the three directions (forward/backward, up/down, right/left). Frequency: 105510Hz, Amplitude: 1.5mm PP per minute cycle. |
| Shock Test | Inductance deviation is within 3.0% after the test with gum-block shock testing machine, once in each of the three perpendicular axis directions. Shock acceleration: 981m/s. |
| Humidity Test | Inductance deviation is within 5.0% and no structure and electric defects can be found after 964 hours test under 9095% relative humidity and 402 temperature, followed by 1 hour storage under room ambient conditions after wiping with a dry cloth. |