Product Overview
This document outlines the specifications for the SBCM.7060.YF series common mode chokes. It details the product's construction, electrical characteristics, dimensions, packaging, and reliability test results. This product is designed for applications requiring effective noise suppression.
Product Attributes
- Brand: Sorede ()
- Origin: Shenzhen, China
- Certifications: UL (for wire material)
Technical Specifications
| Part Number | Impedance (@100MHz) Min | Impedance (@100MHz) Typ | DCR (m) max. | Rated Current (A) Max | Rated Volt. (Vdc)max | IR (M) min. | MARK |
|---|---|---|---|---|---|---|---|
| SBCM.7060.YF400TT00 | 40 | 70 | 5 | 15 | 125 | 10 | 400 |
| SBCM.7060.YF101TT00 | 100 | 140 | 10 | 9 | 125 | 10 | 101 |
| SBCM.7060.YF301TT00 | 225 | 300 | 10 | 5 | 125 | 10 | 301 |
| SBCM.7060.YF501TT00 | 275 | 450 | 10 | 5 | 125 | 10 | 501 |
| SBCM.7060.YF601TT00 | 500 | 700 | 15 | 4 | 125 | 10 | 601 |
| SBCM.7060.YF701TT00 | 500 | 700 | 15 | 4 | 125 | 10 | 701 |
| SBCM.7060.YF102TT00 | 800 | 1020 | 17 | 3 | 125 | 10 | 102 |
| SBCM.7060.YF132TT00 | 910 | 1300 | 21 | 2.5 | 125 | 10 | 132 |
| SBCM.7060.YF272TT00 | 2000 | 2700 | 63 | 1 | 125 | 10 | 272 |
| SBCM.7060.YF302TT00 | 2500 | 3000 | 75 | 0.9 | 125 | 10 | 302 |
| Item | Specifications | Test Methods |
|---|---|---|
| Solder- Ability | More than 90% of termination should be covered with new solder. | Solder: Sn, Temperature: 255+5/-0, Flux: rosin, Duration: 3.50.5s |
| Leaching Resistance | More than 75% of termination Should be covered with new solder. | Solder: Sn, Temperature: 270+2/-0, Flux: rosin, Duration: 100.5s |
| Drop | No mechanical damage shall be noticed; Impedance shall be within 20% of the initial value. | Drop 10 times on a concrete floor from a height of 1m. |
| Vibration | N/A | Frequency: 10 to 55Hz, Amplitude: 1.52mm, Direction and time: X, Y and Z directions for 2 hours each. |
| Humidity resistance | N/A | Test condition: Temp. 405, Humidity: 90%~95%, Test time: 50012hr. Measurement method: Stabilized at normal condition for 24 hours before test. |
| High temperature resistance | N/A | Test condition: Applied rated current, Temp. 855, Test time: 50012hr. Measurement method: Stabilized at normal condition for 24 hours before test. |
| Low temperature resistance | No mechanical damage shall be noticed; Impedance shall be within 20% of the initial value. | Test condition: Temp. -405, Test time: 50012hr. Measurement method: Stabilized at normal condition for 24 hours before test. |
| Thermal shock | N/A | Test condition: 1) Temp. -40, time: 303min; 2) Temp. +85, time: 303min. 100 cycles. Measurement method: Stabilized at normal condition for 24 hours before test. |