Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Stable 125 MHz Frequency Clock Oscillator Raltron XCO583IV11-125000 for High Frequency Applications factory
<
quality Stable 125 MHz Frequency Clock Oscillator Raltron XCO583IV11-125000 for High Frequency Applications factory
>
Specifications
Mfr. Part #:
XCO583IV11-125.000
Key Attributes
Model Number: XCO583IV11-125.000
Product Description

Raltron Electronics XCO583IV11-125.000 LVDS Clock Oscillator

The Raltron Electronics XCO583IV11-125.000 is an LVDS clock oscillator designed for high-frequency applications. It offers precise timing with a nominal frequency of 125.000 MHz and operates with a stable supply voltage. This oscillator is suitable for various electronic systems requiring reliable clock signals.

Product Attributes

  • Brand: Raltron Electronics
  • Model: XCO583IV11-125.000
  • Origin: U.S.A.
  • Certifications: REACH-SVHC Compliant, RoHS Compliant
  • Termination Finish: Au

Technical Specifications

Parameter Symbol Conditions Value Unit
ELECTRICAL SPECIFICATION
Frequency, nom. Fo +25C, 3.3V and 50 load to Vcc - 2v 125.000 MHz
Supply Voltage, nom. Vcc 5% 3.3 V
Duty Cycle DC Measured at 50% of vcc 45/55 %
RMS Phase Jitter, typ J RMS Fj=12 kHz20MHz 0.7 ps
Overall Freq. Stability max f/fc Ta=-20C+85C, load and supply variations, initial calibration, aging shock and vibration. 25 ppm
Enable Option En PIN 1= HIGH or open (min) 0.75xVcc V
Disable Option Dis PIN 1= LOW (max) 0.3 V
Operating Temperature Range Ta -40 to+85 C
Storage Temperature Range T(stg) -55.+125 C
Absolute Voltage Range Vcc, (abs) Non-destructive, DC -0.5+4.6 V
LVDS OUTPUT CHARACTERISTICS
Differential Output Voltage VOD 5% 0.6 V
Offset Voltage VOS DC 1.3 V
Rise/Fall Time Tr/Tf 0.35 ns
Supply Current Is 60 mA
Output Load OCL Differential 100 load connected between each output 100
REFLOW PROFILE
Temperature Min Preheat TSMIN 150 C
Temperature Max Preheat TSMAX 200 C
Time (TSMIN to TSMAX) tS 60-180 sec.
Temperature TL TL 217 C
Peak Temperature TP 260 C
Ramp-up rate RUP 3 C/sec max.
Ramp-down rate RDOWN 6 C/sec max.
Time within 5C of Peak Temperature tP 20-40 sec.
Time t[25C] to Peak Temperature t[25C] to Peak 480 sec.
Time tL tL 60-150 sec.
ENVIRONMENTAL
MOISTURE SENSITIVITY LEVEL 1