Product Overview
This product is a compliant component with detailed specifications for part numbering, mechanical dimensions, marking, and electrical characteristics. It is designed for applications requiring specific inductance, DC resistance, rated current, and saturation current values. The product is RoHS and REACH compliant.
Product Attributes
- Certifications: RoHS, REACH
Technical Specifications
| Part Number | Inductance (uH) 20% | DC Resistance (m) Typical | DC Resistance (m) MAX. | Rated Current (A) | I sat (A) Typical |
| MCS0420-R10MN2 | 0.10 | 3.5 | 4.0 | 12.0 | 22.0 |
| MCS0420-R12MN2 | 0.12 | 4.5 | 5.0 | 12.0 | 12.0 |
| MCS0420-R15MN2 | 0.15 | 6.0 | 6.6 | 9.0 | 13.0 |
| MCS0420-R22MN2 | 0.22 | 6.0 | 6.6 | 9.0 | 12.5 |
| MCS0420-R33MN2 | 0.33 | 9.6 | 11.0 | 10.0 | 13.0 |
| MCS0420-R47MN2 | 0.47 | 12.5 | 14.0 | 7.0 | 9.5 |
| MCS0420-R56MN2 | 0.56 | 14.0 | 16.0 | 6.5 | 10.0 |
| MCS0420-R68MN2 | 0.68 | 16.0 | 18.0 | 6.0 | 9.0 |
| MCS0420-1R0MN2 | 1.0 | 24.0 | 27.0 | 4.5 | 7.0 |
| MCS0420-1R2MN2 | 1.2 | 24.0 | 27.0 | 4.5 | 7.0 |
| MCS0420-1R5MN2 | 1.5 | 38.0 | 46.0 | 4.0 | 6.0 |
| MCS0420-2R2MN2 | 2.2 | 52.0 | 58.0 | 3.0 | 5.0 |
| MCS0420-3R3MN2 | 3.3 | 74.0 | 87.0 | 2.5 | 4.0 |
| MCS0420-4R7MN2 | 4.7 | 98.0 | 110.0 | 2.2 | 3.5 |
| MCS0420-5R6MN2 | 5.6 | 105.0 | 115.0 | 1.8 | 3.5 |
| MCS0420-6R8MN2 | 6.8 | 160.0 | 175.0 | 1.5 | 2.5 |
| MCS0420-100MN1 | 10.0 | 256.0 | 282.0 | 1.2 | 2.2 |
Mechanical Dimensions
| Dimension | Tolerance |
| M1 | 4.45 0.25 |
| M2 | 4.0 0.3 |
| M3 | 1.8 0.2 |
| M4 | 1.5 0.3 |
| M5 | 0.8 0.3 |
Marking
Marking Direction: PAD on the left and right sides, font facing up. Example: 1R0 Stands for Marking1.0H
Notes
- Test Frequency: 100KHz, 1.0V
- All test data is referenced to 25 ambient.
- Operating Temperature Range: -25~+125.
- Storage Temperature Range: -20~+40(<60% R.H.).
- Rated Current: DC current(A) that will cause an approximate T of 40.
- I sat: DC current (A) that will cause Lo to drop approximately 30%.
- The part temperature (ambient + temp rise) should not exceed 125 under worst case operating conditions.
- Circuit design, component placement, PWB trace size and thickness, airflow and other cooling provisions all affect the part temperature. Part temperature should be verified.
- MSL: Level 1
2411071804_PSA-MCS0420-1R0MN2_C442396.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible