Specifications
Voltage Rating:
6.3V
Capacitance:
4.7uF
Temperature Coefficient:
X5R
Tolerance:
±20%
Mfr. Part #:
GRM155R60J475ME87D
Package:
0402
Key Attributes
Model Number:
GRM155R60J475ME87D
Product Description
Product Overview
Chip Multilayer Ceramic Capacitors for General Electronic Equipment. Designed for general-purpose applications, these capacitors offer reliable performance and are suitable for a wide range of electronic devices.
Product Attributes
- Brand: MURATA
Technical Specifications
| Part Number | Size Code | Temperature Characteristics | Nominal Capacitance | Capacitance Tolerance | Rated Voltage | Packaging | Packaging Code | Dimensions (L/W) | Dimensions (T) |
| GRM155R60J475ME87 | 0402 | X5R (EIA) | 4.7uF | +/-20% | DC 6.3 V | 10000 pcs./Reel | D | 0.4 | 0.3 |
| GRM155R60J475ME87 | 0402 | X5R (EIA) | 4.7uF | +/-20% | DC 6.3 V | 40000 pcs./Reel | J | 0.4 | 0.3 |
| Item | Specification | Test Method |
| Rated Voltage | Defined as the maximum voltage which may be applied continuously to the capacitor. | Shown in Rated value. |
| Appearance | No defects or abnormalities. | Visual inspection. |
| Dimension | Shown in Rated value. | Using Measuring instrument of dimension. |
| Voltage Proof | No defects or abnormalities. | Measurement Point : Between the terminations Test Voltage : 250% of the rated voltage Applied Time : 1s to 5s Charge/Discharge Current : 50mA max. |
| Insulation Resistance(I.R.) | More than 50F | Measurement Temperature:Room Temperature Measurement Point : Between the terminations Measurement Voltage : Rated Voltage Charging Time : 1min Charge/Discharge Current : 50mA max. |
| Capacitance | Shown in Rated value. | Measurement Temperature:Room Temperature Measurement Frequency : 1.0+/-0.1kHz Measurement Voltage : 0.5+/-0.1Vrms |
| Q or Dissipation Factor (D.F.) | DF:0.1 max. | Measurement Temperature : Room Temperature Measurement Frequency : 1.0+/-0.1kHz Measurement Voltage : 0.5+/-0.1Vrms |
| Capacitance Change (Temperature Characteristics) | Within +/-15% | Measurement Temperature: Room Temperature Measurement Voltage : Less than 1.0Vrms (Refer to the individual data sheet) Pre-treatment : Perform a heat treatment at 150+0/-10C for 1hour and then let sit for 24+/-2hours at room temperature, then measure. |
| Adhesive Strength | No removal of the terminations or other defect should occur. | Solder the capacitor on the test substrate shown in Fig.3. Termination Applied Force : 5N Holding Time : 10+/-1 Applied Direction : In parallel with the test substrate and vertical with the capacitor side |
| Vibration | Appearance: No defects or abnormalities. Capacitance: Within the specified initial value. Q or D.F.: Within the specified initial value. | Solder the capacitor on the test substrate shown in Fig.3. Kind of Vibration : A simple harmonic motion 10Hz to 55Hz to 10Hz Vibration Time : 1min Total Amplitude : 1.5mm This motion should be applied for a period of 2hours in each 3 mutually perpendicular directions(total of 6hours). |
| Substrate Bending Test | Appearance: No defects or abnormalities. Capacitance: Within +/-10% | Solder the capacitor on the test substrate shown in Fig.1. Pressurization Method : Shown in Fig.2. Flexure : 1mm Change Holding Time : 5+/-1s Soldering Method : Reflow soldering |
| Solderability | 95% of the terminations is to be soldered evenly and continuously. | Solder bath method Flux : Solution of rosin ethanol 25(mass)% Preheat : 80 to 12010s to 30s Solder : Sn-3.0Ag-0.5Cu(Lead Free Solder) Test Temp. : 245+/-5 Test Time : 2+/-0.5s |
| Resistance to Soldering Heat | Appearance: No defects or abnormalities. Capacitance: Within +/-15% Change Q or D.F.: Within the specified initial value. I.R.: Within the specified initial value. Voltage Proof: No defects. | Solder bath method Solder : Sn-3.0Ag-0.5Cu(Lead Free Solder) Solder Temp. : 270+/-5 Test Time : 10+/-0.5s Preheat Temp. : 120 to 150 Preheat Time : 1min I.R. Pre-treatment : Perform a heat treatment at 150+0/-10C for 1hour and then let sit for 24+/-2hours at room temperature, then measure. Post-treatment : Let sit for 24+/-2hours at room temperature, then measure. Voltage Proof Post-treatment : Let sit for 24+/-2hours at room temperature, then measure. |
| Temperature Sudden Change | Appearance: No defects or abnormalities. Capacitance: Within +/-7.5% Change Q or D.F.: Within the specified initial value. I.R.: Within the specified initial value. Voltage Proof: No defects. | Solder the capacitor on the test substrate shown in Fig.3. Sudden Cycles : 5 cycles Pre-treatment : Perform a heat treatment at 150+0/-10C for 1hour and then let sit for 24+/-2hours at room temperature, then measure. Post-treatment : Let sit for 24+/-2hours at room temperature, then measure. Voltage Proof Pre-treatment : Perform a heat treatment at 150+0/-10C for 1hour and then let sit for 24+/-2hours at room temperature, then measure. Post-treatment : Let sit for 24+/-2hours at room temperature, then measure. |
| High Temperature High Humidity (Steady) | Appearance: No defects or abnormalities. Capacitance: Within +/-12.5% Change Q or D.F.: DF:0.2 max. I.R.: More than 500M or 12.5F (Whichever is smaller) | Solder the capacitor on the test substrate shown in Fig.3. Test Temperature : 40+/-2 Test Humidity : 90%RH to 95%RH (Steady) Test Time : 500+/-12h Test Voltage : Rated Voltage Charge/Discharge Current : 50mA max. Pre-treatment : Perform a heat treatment at 150+0/-10C for 1hour and then let sit for 24+/-2hours at room temperature, then measure. Post-treatment : Perform a heat treatment at 150+0/-10C for 1hour and then let sit for 24+/-2hours at room temperature, then measure. |
| Durability | Appearance: No defects or abnormalities. Capacitance: Within +/-12.5% Change Q or D.F.: DF:0.2 max. I.R.: More than 1000M or 25F (Whichever is smaller) | Solder the capacitor on the test substrate shown in Fig.3. Test Temperature : Maximum Operating Temperature+/-3 Test Time : 1000+/-12h Test Voltage : 100% of the rated voltage Charge/Discharge Current : 50mA max. Pre-treatment : Perform a heat treatment at 150+0/-10C for 1hour and then let sit for 24+/-2hours at room temperature, then measure. Post-treatment : Perform a heat treatment at 150+0/-10C for 1hour and then let sit for 24+/-2hours at room temperature, then measure. |