Online Service

Online Service

Contact Person
+86 13528435210
quality Long life polar aluminum electrolytic capacitor Man Yue Tech EHP157M2WN30SZ 450V 150F for industrial factory
<
quality Long life polar aluminum electrolytic capacitor Man Yue Tech EHP157M2WN30SZ 450V 150F for industrial factory
>
Specifications
Capacitance:
150uF
Height - Seated (Max):
30mm
Voltage Rating:
450V
Diameter:
22mm
Tolerance:
±20%
Mfr. Part #:
EHP157M2WN30SZ
Package:
Through Hole,D22xL30mm
Key Attributes
Model Number: EHP157M2WN30SZ
Product Description

Product Overview

The SAMXON HP Series Aluminum Electrolytic Capacitors are polar, foil-type capacitors designed for use in electronic equipment. Meeting IEC60384 standards, these capacitors offer reliable performance with a focus on quality and durability. They are suitable for a wide range of electronic applications requiring stable capacitance and voltage handling.

Product Attributes

  • Brand: SAMXON
  • Series: HP Series
  • Type: Polar Aluminum Electrolytic Capacitor (Foil Type)
  • Construction: Single-ended type with aluminum case, PET sleeve, solder-coated copper clad steel terminals, rubber-laminated bakelite seal.
  • Compliance: Meets IEC60384 standards.

Technical Specifications

General Specifications:

Specification Value
Rated Voltage (WVdc) 450V
Capacitance (Cap.) 150F
Capacitance Tolerance -20% ~ +20%
Temperature Range -25 ~ 105
Dissipation Factor (tan) at 120Hz, 20 0.20
Leakage Current (A, 5min) 779A
Max Ripple Current at 105, 120Hz (Arms) 0.74A
Load Lifetime (Hrs) 2000 Hrs
Dimension (DL) 22mm 30mm
Sleeve Material PET

Part Number System Example: EHP157M2WN30SZ

  • Series: EHP
  • Capacitance Code: 157 (150F)
  • Rated Voltage Code: 2W (450V)
  • Type Code: SZ (Z-TYPE)
  • Capacitance Tolerance: M (-20% ~ +20%)
  • Diameter Code: N (22mm)
  • Length Code: 30 (30mm)

Detailed Performance Characteristics:

Item Condition Criteria
Rated Voltage (WV) & Surge Voltage (SV) Refer to Table 2 for various ratings.
Nominal Capacitance (Tolerance) 120Hz12Hz, 0.5Vrms, 202 Within specified tolerance.
Leakage Current 1k10 resistor in series for 5 min. Refer to Table 1.
tan 120Hz12Hz, 0.5Vrms, 202 Refer to Table 1.
Terminal Strength 25N static load, axial direction, 30s. No intermittent contact, open/short circuit, or mechanical damage.
Temperature Characteristics -40(-25), 20, 105 cycles. tan within limit, leakage current 8x specified value (at -40), impedance ratio limits apply.
Load Life Test 1052, rated ripple current, DC bias. Leakage current satisfied, Capacitance change 20%, tan 200% of specified, no electrolyte leakage.
Shelf Life Test 1052 for 1000+48/0 hrs, then rated voltage applied. Leakage current satisfied, Capacitance change 15%, tan 150% of specified, no electrolyte leakage.
Surge Test 1000 cycles of charge/discharge with surge voltage. Leakage current specified value, Capacitance change 15%, tan specified value, no electrolyte leakage.
Vibration Test 10Hz ~ 55Hz, 1.5mm amplitude, 3 directions. No mechanical damage, no electrolyte leakage/swelling, legible markings, no intermittent contact/open/short circuit.
Solderability Test 2453, 2mm depth, 252.5mm/s, 30.5s. Minimum 95% of immersed surface coated.
Resistance to Solder Heat Test 2605 for 101s or 40010 for 3+0/-1s. Leakage current specified value, Capacitance change 10%, tan specified value, no electrolyte leakage.
Change of Temperature Test Temperature cycles (-40 to +105). Leakage current specified value, tan specified value, no electrolyte leakage.
Damp Heat Test 90~95% RH at 402 for 5008 hours. Leakage current specified value, Capacitance change 20%, tan 120% of specified, no electrolyte leakage.
Vent Test DC reverse voltage test with specified current. Vent operates with no dangerous conditions.
Maximum Permissible Ripple Current 120Hz, at maximum operating temperature. Refer to Table 1 and frequency multipliers.

Environment-related Substances:

Refer to the latest document of Environment-related Substances standard (WI-HSPM-QA-072) for controlled substances.

Application Guidelines:

  • Circuit Design: Consider effects of temperature and frequency on electrical parameters. Avoid reverse voltage, over-voltage, and exceeding ripple current limits. Use appropriate capacitors for charge/discharge applications.
  • Series/Parallel Connection: Implement careful wiring for parallel connections and use shunt resistors for series connections to manage voltage imbalances.
  • Mounting Considerations: Ensure proper clearance for pressure relief vents, avoid circuit board runs under the capacitor, and match lead spacing to hole spacing.
  • Electrical Isolation: Ensure complete electrical isolation of the capacitor.
  • Capacitor Handling: Handle with care to avoid mechanical or electrical damage. Verify polarity before insertion.
  • Soldering: Observe specified temperature and time limits. Avoid stress on leads.
  • Circuit Board Cleaning: Use suitable cleaning solvents and ensure thorough drying. Avoid specified solvent groups.
  • Adhesives/Coating Agents: Use materials without halogenated solvents and dry thoroughly.
  • Precautions: Avoid extreme temperatures, direct contact with water/oil, high humidity, toxic gases, radiation, vibration, and shock. Avoid touching terminals to prevent electric shock.
  • Emergency Procedures: In case of vent operation, immediately turn off equipment. Avoid contact with escaping electrolyte gas.
  • Long Term Storage: Recondition capacitors stored for over one year by applying rated voltage with a current limiting resistor.
  • Disposal: Incinerate after crushing/puncturing or dispose of as solid waste, following local laws.

2410121623_Man-Yue-Tech-EHP157M2WN30SZ_C238411.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max