Product Overview
The SAMXON GT Series Aluminum Electrolytic Capacitors are polar, foil-type capacitors designed for use in electronic equipment and meet IEC60384 standards. These single-ended capacitors feature an aluminum case impregnated with electrolyte and sealed with end seal rubber, finished with a vinyl sleeve. They are suitable for general electronic applications where reliable performance and specific electrical characteristics are required. The series offers a wide operating temperature range and is designed to meet demanding application requirements.
Product Attributes
- Brand: SAMXON
- Manufacturer: MAN YUE ELECTRONICS COMPANY LIMITED
- Series: GT Series
- Construction: Single ended, foil type, aluminum case with vinyl sleeve
- Materials: Tinned CP wire (Pb Free) for lead line, Aluminum wire for terminal, Rubber for sealing, Formed aluminum foil for anode, Etched or formed aluminum foil for cathode, Aluminum case, PET sleeve, Electrolyte paper separator.
- Compliance: Meets IEC60384 standards.
Technical Specifications
| SAMXON Part No. | WV (Vdc) | Cap. (F) | Cap. tolerance | Temp. range() | tan (120Hz, 20) | Leakage Current (A, 2min) | Max Ripple Current at 105 100KHz (mA rms) | Impedance at 20 100kHz (max) | Load lifetime (Hrs) | Dimension (mm) DL | F1 | d |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| EGT226M1HD11HB**P-R | 50 | 22 | -20%~+20% | -40~105 | 0.10 | 11 | 180 | 0.7 | 5000 | 5X11 | 2.0 | 0.5 |
| Rated voltage (WV) V.DC | 6.3 | 10 | 16 | 25 | 35 | 50 | 63 | 100 |
|---|---|---|---|---|---|---|---|---|
| Surge voltage (SV) V.DC | 8 | 13 | 20 | 31 | 44 | 63 | 79 | 125 |
| Lead line Material | Terminal Material | Sealing Material | Anode Foil Material | Cathode Foil Material | Case Material | Sleeve Material | Separator Material |
|---|---|---|---|---|---|---|---|
| Tinned CP wire (Pb Free) | Aluminum wire | Rubber | Formed aluminum foil | Etched aluminum foil or formed aluminum foil | Aluminum case | PET | Electrolyte paper |
| Test Condition | Criteria |
|---|---|
| Capacitance (Tolerance) Measuring Frequency: 120Hz12Hz Measuring Voltage: Not more than 0.5Vrms Measuring Temperature: 202 | Shall be within the specified capacitance tolerance. |
| Leakage current Connecting the capacitor with a protective resistor (1k 10 ) in series for 2 minutes, and then, measure Leakage Current. | Refer to Table 1 |
| tan See 4.2, Norm Capacitance, for measuring frequency, voltage and temperature. | Refer to Table 1 |
| Terminal strength Tensile Strength of Terminals: applied force to the terminal in lead out direction for 101 seconds. Bending Strength of Terminals: applied force to bent the terminal (1~4 mm from the rubber) for 90o within 2~3 seconds, and then bent it for 90o to its original position within 2~3 seconds. | No noticeable changes shall be found, no breakage or looseness at the terminal. |
| Load life test According to IEC60384-4No.4.13 methods, temperature of 105C 2 with DC bias voltage plus the rated ripple current for Table 1. (The sum of DC and ripple peak voltage shall not exceed the rated working voltage). Tested after 16 hours recovering time. | Leakage current: Value in 4.3 shall be satisfied Capacitance Change: Within 25% of initial value. tan: Not more than 200% of the specified value. Appearance: There shall be no leakage of electrolyte. |
| Shelf life test Stored with no voltage applied at 1052 for 1000+48/0 hours. Stabilized at room temperature for 4~8 hours. Rated DC voltage applied for 30min through a series limiting resistor(1k100 ). | Leakage current: Value in 4.3 shall be satisfied Capacitance Change: Within 25 of initial value. tan: Not more than 200%of the specified value. Appearance: There shall be no leakage of electrolyte. |
| Surge test Applied a surge voltage to the capacitor connected with a (100 50)/CR (k) resistor. 1000 cycles, each consisting of charge of 30 5s, followed discharge of 5 min 30s. Test temperature: 15~35. CR :Nominal Capacitance ( F) | Leakage current: Not more than the specified value. Capacitance Change: Within 15% of initial value. tan: Not more than the specified value. Appearance: There shall be no leakage of electrolyte. |
| Vibration test 10Hz ~ 55Hz, Peak to peak amplitude: 1.5mm. Sweep rate: 10Hz ~ 55Hz ~ 10Hz in about 1 minute. Applied for 2 hours in each of 3 mutually perpendicular directions. | Inner construction: No intermittent contacts, open or short circuiting. No damage of tab terminals or electrodes. Appearance: No mechanical damage in terminal. No leakage of electrolyte or swelling of the case. The markings shall be legible. |
| Solderability test Soldering temperature: 2453C Dipping depth: 2mm Dipping speed: 252.5mm/s Dipping time: 30.5s | Coating quality: A minimum of 95% of the surface being immersed |
| Resistance to solder heat test Terminals immersed into solder bath at 2605for10 1seconds or 40010for3 0 1 seconds to 1.5~2.0mm from the body of capacitor. Left under normal temperature and humidity for 1~2 hours before measurement. | Leakage current: Not more than the specified value. Capacitance Change: Within 10% of initial value. tan: Not more than the specified value. Appearance: There shall be no leakage of electrolyte. |
| Change of temperature test Temperature Cycle: IEC60384-4No.4.7 methods. 5 cycles: (1)+20 3 Minutes, (2)Rated low temp (-40 or -25) 302 Minutes, (3)Rated high temp (+105) 302 Minutes. | Leakage current: Not more than the specified value. tan: Not more than the specified value. Appearance: There shall be no leakage of electrolyte. |
| Damp heat test Humidity Test: IEC60384-4No.4.12 methods. 5008 hours in 90~95% R H .at 402. | Leakage current: Not more than the specified value. Capacitance Change: Within 20% of initial value. tan: Not more than 120% of the specified value. Appearance: There shall be no leakage of electrolyte. |
| Vent test Applies to products with vent (diameter 6.3mm). DC test: Reversed polarity to DC power source. Applied current from Table 3. | The vent shall operate with no dangerous conditions such as flames or dispersion of pieces of the capacitor and/or case. |
| Maximum permissible (ripple current) Maximum A.C current at 120Hz and can be applied at maximum operating temperature. The combined value of D.C voltage and the peak A.C voltage shall not exceed the rated voltage and shall not reverse voltage. | Refer to Table 1 for specific values based on capacitance and frequency. |
2411272156_Man-Yue-Tech-EGT226M1HD11HB_C2903580.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible