Product Overview
The SAMXON GT Series Aluminum Electrolytic Capacitors are polar, foil-type capacitors designed for use in electronic equipment, meeting IEC60384 standards. These capacitors are constructed with a single-ended design, featuring an aluminum case sealed with end seal rubber and a vinyl sleeve. They are suitable for applications requiring reliable performance across a wide temperature range (-40 to 105) and offer various technical specifications including rated voltage, capacitance, leakage current, and ripple current handling.
Product Attributes
- Brand: SAMXON
- Series: GT Series
- Construction Type: Single Ended, Foil Type
- Case Material: Aluminum
- Sleeve Material: PET
- Sealing Material: Rubber
- Lead Line Material: Tinned CP wire (Pb Free)
- Terminal Material: Aluminum wire
- Separator Material: Electrolyte paper
Technical Specifications
| SAMXON Part No. | WV (Vdc) | Cap. (F) | Cap. tolerance | Temp. range() | tan (120Hz, 20) | Leakage Current (A, 2min) | Max Ripple Current at 105 100KHz (mA rms) | Impedance at 25 100KHz (max) | Load lifetime (Hrs) | Dimension (mm) DA | Sleeve F | d |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| EGT567M1JI20CB**P-R | 63 | 560 | -20%~+20% | -40~105 | 0.09 | 353 | 690 | 0.128 | 10000 | 12.5X20 | 5.0 | 0.6 |
General Characteristics
| Item | Performance |
|---|---|
| Rated voltage (WV) | 6.3, 10, 16, 25, 35, 50, 63, 100 V.DC |
| Surge voltage (SV) | 8, 13, 20, 32, 44, 63, 79, 125 V.DC |
| Nominal capacitance (Tolerance) | Measured at 120Hz12Hz, 0.5Vrms, 202. Shall be within specified tolerance. |
| Leakage current | Measured after connecting with a protective resistor (1k10) in series for 2 minutes. Refer to Table 1. |
| tan | Measured at 120Hz12Hz, 0.5Vrms, 202. Refer to Table 1. |
| Terminal strength (Tensile) | 0.5mm and less: 5 N (0.51 kgf); Over 0.5mm to 0.8mm: 10 N (1.0 kgf) |
| Terminal strength (Bending) | 0.5mm and less: 2.5 N (0.25 kgf); Over 0.5mm to 0.8mm: 5 N (0.51 kgf) |
| Temperature characteristic | Tests performed at -40, 20, and 105. Criteria include tan limits, leakage current limits, and impedance ratio limits at low temperatures. |
| Load life test | Tested at 105C 2 with DC bias and rated ripple current for specified hours. Criteria include leakage current, capacitance change (25%), tan (200% of specified), and appearance. |
| Shelf life test | Stored at 1052 for 1000+48/0 hours. Criteria include leakage current, capacitance change (25%), tan (200% of specified), and appearance. |
| Surge test | 1000 cycles of charge (305s) and discharge (5 min 30s) with surge voltage. Criteria include leakage current, capacitance change (15%), tan, and appearance. |
| Vibration test | 10Hz ~ 55Hz, 1.5mm amplitude for 2 hours in 3 directions. Criteria include no intermittent contacts, open/short circuits, or mechanical damage. |
| Solderability test | Sn-Cu solder at 2503, 30.5s dipping time. Minimum 95% surface coating quality. |
| Resistance to solder heat test | 2605 for 101s or 40010 for 1-0+1s. Criteria include leakage current, capacitance change (10%), tan, and appearance. |
| Change of temperature test | 5 cycles of temperature changes between +20, rated low temperature (-40/-25), and +105. Criteria include leakage current, tan, and appearance. |
| Damp heat test | 5008 hours at 90~95% RH, 402. Criteria include leakage current, capacitance change (20%), tan (120% of specified), and appearance. |
| Vent test | Applies to vented products (diameter 6.3mm). DC test with reversed polarity. Vent shall operate with no dangerous conditions. |
| Maximum permissible (ripple current) | Maximum AC current at 120Hz and maximum operating temperature. Frequency multipliers and temperature coefficients provided. |
Environment-related Substances
Controlled substances include Heavy metals (Cadmium, Lead, Mercury, Hexavalent chromium), Chlorinated organic compounds (PCB, PCN, PCT, SCCP), Brominated organic compounds (PBB, PBDE), Organotin compounds (TBT, TPT), Asbestos, Specific azo compounds, Formaldehyde, Beryllium oxide, Beryllium copper, Specific phthalates, Hydrofluorocarbon (HFC), Perfluorocarbon (PFC), Perfluorooctane sulfonates (PFOS), and Specific Benzotriazole. Reference to the latest document "Environment-related Substances standard" (WI-HSPM-QA-072) is required.
Application Guidelines
Circuit Design: Electrical parameters vary with temperature and frequency. Consider effects on leakage current, capacitance, and ESR. Avoid reverse voltage, over voltage, excessive ripple current, and pulse current exceeding 10 times rated ripple current. For series/parallel connections, consider voltage/current imbalances. Ensure adequate clearance for pressure relief vents and avoid wiring near vents. Use appropriate mounting adhesives and coating agents. Ensure electrical isolation. Product endurance should take the sample as the standard. Collect date code within 6 months for load or shelf life tests. The vinyl sleeve is for marking and not electrical insulation.
Capacitor Handling Techniques: Do not reuse capacitors from used equipment. Discharge transient recovery voltage if required. Recondition capacitors stored for long periods by gradually applying rated voltage with a current-limiting resistor. Avoid using dropped, dented, or crushed capacitors. Verify capacitance, rated voltage, and polarity before insertion. Avoid stress on leads during insertion and soldering. Observe soldering temperature and time specifications. Avoid immersing capacitor body into solder bath. Do not allow other components to touch the capacitor during soldering. Avoid rapid temperature rises. Avoid movement of the capacitor after soldering. Do not use the capacitor as a handle. Avoid striking the capacitor after assembly.
Circuit Board Cleaning: Use suitable cleaning solvents, rinse, and dry thoroughly. Avoid ozone-depleting agents, halogenated solvents (except for solvent-resistant types), alkali solvents, petroleum-based solvents, xylene, and acetone. Monitor contamination levels. Consult for acceptable cleaning solvents or methods.
Precautions for using capacitors: Do not store or use outside rated temperature range, in contact with water/salt water/oil, high humidity, toxic gases, ozone, radiation, UV rays, or exceeding vibration/shock requirements. Avoid touching terminals due to electric shock risk. Avoid short-circuiting terminals with conductive materials or liquids.
Emergency Procedures: If pressure relief vent operates, immediately turn off equipment and disconnect power. Avoid contact with escaping electrolyte gas. Flush eyes with water if electrolyte enters. Gargle with water if ingested. Wash skin with soap and water if electrolyte contacts skin.
Long Term Storage: Leakage current increases with long storage. Recondition capacitors older than one year by applying rated voltage in series with a 1000 resistor for 30 minutes. Products with date codes over eighteen months should be returned for confirmation.
Capacitor Disposal: Incinerate after crushing or puncturing the can wall. Dispose of as solid waste. Follow local laws for specific disposal requirements.