Product Overview
The SAMXON GY Series Aluminum Electrolytic Capacitors are polar, foil-type capacitors designed for use in electronic equipment. Meeting IEC60384 standards, these capacitors are constructed with an aluminum case, sealed with end seal rubber, and finished with a PET vinyl sleeve. They are suitable for general electronic applications where reliable performance and specific electrical characteristics are required.
Product Attributes
- Brand: SAMXON
- Series: GY Series
- Construction: Single ended type, foil type
- Case Material: Aluminum
- Sleeve Material: PET
- Sealing Material: Rubber
- Lead Wire Material: Tinned CP wire (Pb Free)
- Terminal Material: Aluminum wire
- Separator Material: Electrolyte paper
- Safety Vent: Available for 6.3mm
Technical Specifications
| SAMXON Part No. | WV (Vdc) | Cap. (F) | Cap. tolerance | Temp. range() | tan (120Hz, 20) | Leakage Current (A, 2min) | Max Ripple Current at 105 100KHz (mA rms) | Impedance at 20 100kHz (max) | Load lifetime (Hrs) | Dimension (mm) D L | Sleeve D L | F | d |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| EGY687M2AK30RR**P | 100 | 680 | -20%~+20% | -40~105 | 0.08 | 680 | 980 | 0.72 | 10000 | 16X30 | 16X30 | 7.5 | 0.8 |
Standard Atmospheric Conditions for Measurement
- Ambient temperature: 15C to 35C
- Relative humidity: 45% to 85%
- Air Pressure: 86kPa to 106kPa
Conditions for Measurement (if doubt)
- Ambient temperature: 20C 2C
- Relative humidity: 60% to 70%
- Air Pressure: 86kPa to 106kPa
Operating Temperature Range
Refer to Table 1 for operating temperature range. Detailed information is available in Table 2.
Rated Voltage & Surge Voltage (Table 2)
| WV (V.DC) | SV (V.DC) |
|---|---|
| 6.3 | 8 |
| 10 | 13 |
| 16 | 20 |
| 25 | 32 |
| 35 | 44 |
| 50 | 63 |
| 63 | 79 |
| 100 | 125 |
Capacitance Measurement Conditions
- Measuring Frequency: 120Hz 12Hz
- Measuring Voltage: Not more than 0.5Vrms
- Measuring Temperature: 20 2
Terminal Strength
| Diameter of lead wire | Tensile force N (kgf) | Bending force N (kgf) |
|---|---|---|
| 0.5mm and less | 5 (0.51) | 2.5 (0.25) |
| Over 0.5mm to 0.8mm | 10 (1.0) | 5 (0.51) |
Temperature Characteristic Impedance Ratio (Z-Temp/Z+20)
| Working Voltage (V) | Z-25/Z+20 | Z-40/Z+20 |
|---|---|---|
| 6.3 | 4 | 8 |
| 10 | 3 | 6 |
| 16 | 2 | 4 |
| 25 | 2 | 3 |
| 35 | 2 | 3 |
| 50 | 2 | 3 |
| 63 | 2 | 3 |
| 100 | 2 | 3 |
For capacitance value > 1000F, Add 0.5 per another 1000F for Z-25/Z+20, Add 1.0 per another 1000F for Z-40/Z+20.
Frequency Multipliers for Ripple Current
| Freq. (Hz) | 120 | 300 | 1K | 100k |
|---|---|---|---|---|
| Coefficient | 0.75 | 0.90 | 0.98 | 1.00 |
Controlled Substances
Refer to the latest document of Environment-related Substances standard(WI-HSPM-QA-072). Includes categories such as Heavy metals, Chlorinated organic compounds, Brominated organic compounds, and others.
Application Guidelines - Circuit Design
- Operating Temperature and Frequency: Electrical parameters vary with temperature and frequency. Consider these changes in circuit design.
- Common Application Conditions to Avoid: Reverse Voltage, Charge/Discharge Applications, Over voltage, Ripple Current.
- Using Two or More Capacitors: Parallel connections may cause ripple current imbalance; series connections may cause voltage imbalance.
Application Guidelines - Capacitor Handling
- Considerations Before Using: Finite life, transient recovery voltage, increased leakage current after long storage, damage from dropping or denting.
- Capacitor Insertion: Verify capacitance, rated voltage, polarity, hole spacing, and avoid stress on leads.
- Soldering: Observe temperature and time specifications, avoid stress on leads, avoid touching capacitor body with soldering iron.
- Circuit Board Cleaning: Use suitable solvents and temperatures, avoid specific solvent groups, ensure thorough drying.
- Mounting Adhesives and Coating Agents: Avoid halogenated solvents and chloroprene based polymers.
Precautions for Using Capacitors
- Environmental Conditions: Avoid extreme temperatures, direct contact with water/oil, high humidity, toxic gases, ozone, radiation, vibration, and shock exceeding specifications.
- Electrical Precautions: Avoid touching terminals, avoid short-circuiting terminals with conductive materials.
Emergency Procedures
- If pressure relief vent operates, immediately turn off equipment.
- Avoid contact with escaping electrolyte gas. Follow first aid procedures for eye/skin contact or ingestion.
Long Term Storage
Leakage current increases with long storage. Reconditioning may be required by applying rated voltage in series with a 1000 resistor for 30 minutes. Products over eighteen months old should be returned for confirmation.
Capacitor Disposal
Incinerate after crushing or puncturing, or dispose of as solid waste. Follow local laws and incinerate at high temperatures to prevent toxic gas release.
2410121611_Man-Yue-Tech-EGY687M2AK30RR_C22462393.pdf