Product Overview
The SAMXON RD Series Aluminum Electrolytic Capacitors are polar, foil-type capacitors designed for use in electronic equipment. Meeting IEC60384 standards, these capacitors are constructed with a single-ended, wound element impregnated with electrolyte and enclosed in an aluminum case, sealed with end seal rubber and finished with a vinyl sleeve. They are suitable for a wide operating temperature range and offer reliable performance with features like safety vents for larger diameters.
Product Attributes
- Brand: SAMXON
- Series: RD Series
- Type: Polar Aluminum Electrolytic Capacitor (foil type)
- Construction: Single ended type
- Sleeve Material: PET
- Lead Line Material: Tinned CP wire (Pb Free)
- Terminal Material: Aluminum wire
- Sealing Material: Rubber
- Case Material: Aluminum case
- Separator Material: Electrolyte paper
Technical Specifications
| SAMXON Part No. | WV (Vdc) | Cap. (F) | Cap tolerance | Temp. range() | tan (120Hz, 20) | Leakage Current (A, 2min) | Max Ripple Current at 105 100KHz (mA rms) | Load lifetime (Hrs) | Dimension (mm) DL | F | d |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ERD225M2WF12RR**P-R | 450 | 2.2 | -20%~+20% | -25~105 | 0.20 | 44.8 | 61 | 8000 | 8X12 | 3.5 | 0.5 |
Key Characteristics & Tests
- Rated Voltage (WV): 160, 200, 220, 250, 350, 400, 420, 450 Vdc
- Surge Voltage (SV): 200, 250, 270, 300, 400, 450, 470, 500 Vdc (corresponding to WV)
- Capacitance Measurement: 120Hz12Hz, 0.5Vrms, 202
- Leakage Current: Refer to Table 1 (specific value for ERD225M2WF12RR**P-R is 44.8 A)
- tan: Refer to Table 1 (specific value for ERD225M2WF12RR**P-R is 0.20)
- Terminal Strength: Tensile and Bending strength specified based on lead wire diameter.
- Temperature Characteristics: Performance evaluated at -40, +105, and +20. Impedance ratio at -25 specified for different working voltages.
- Load Life Test: 105C 2 with DC bias voltage plus rated ripple current for specified duration (e.g., 8000 Hrs for ERD225M2WF12RR**P-R). Criteria include leakage current, capacitance change (20%), tan (200% of specified), and no electrolyte leakage.
- Shelf Life Test: Stored at 1052 for 1000+48/0 hours. Criteria include leakage current, capacitance change (20%), tan (200% of specified), and no electrolyte leakage.
- Surge Test: 1000 cycles of charge/discharge with specified surge voltage. Criteria include leakage current, capacitance change (15%), tan (within specified), and no electrolyte leakage.
- Vibration Test: 10Hz ~ 55Hz, 1.5mm peak to peak amplitude for 2 hours in 3 directions. Criteria include no intermittent contacts, open/short circuits, or mechanical damage.
- Solderability Test: Soldering temperature 2453, dipping time 30.5s. Criteria: minimum 95% surface coated.
- Resistance to Solder Heat Test: Immersed in solder bath at 2605 for 101s or 40010 for 1+0/-1s. Criteria include leakage current, capacitance change (10%), tan (within specified), and no electrolyte leakage.
- Change of Temperature Test: Temperature cycles (-25 to +105). Criteria include leakage current, tan (within specified), and no electrolyte leakage.
- Damp Heat Test: 90~95% RH at 402 for 5008 hours. Criteria include leakage current, capacitance change (20%), tan (120% of specified), and no electrolyte leakage.
- Vent Test: Applicable for products with vents (diameter 6.3mm). Vent operates with no dangerous conditions.
- Maximum Permissible Ripple Current: Specified for various frequencies (120Hz, 1k, 10k, 100k Hz) and capacitance ranges.
Environment-related Substances
Refer to the latest document of Environment-related Substances standard (WI-HSPM-QA-072) for controlled substances.
Application Guidelines
Includes considerations for circuit design (operating temperature, frequency, life expectancy, common application conditions to avoid like reverse voltage, over voltage, ripple current), series/parallel capacitor usage, mounting considerations (circuit boards, hole positioning, pressure relief vents), electrical isolation, product endurance, date code sampling, and capacitor sleeves.
Capacitor Handling Techniques
Provides guidance on considerations before using (finite life, transient recovery voltage, leakage current increase with storage, mechanical damage), insertion (polarity, hole spacing, lead clinching), manual soldering, flow soldering, other soldering considerations, handling after solder, circuit board cleaning (solvent compatibility, drying), mounting adhesives, and coating agents.
Precautions for Using Capacitors
Details environmental conditions to avoid (temperature extremes, water, high humidity, toxic gases, radiation, vibration/shock) and electrical precautions (electric shock, short circuits).
Emergency Procedures
Instructions for handling pressure relief vent operation (turn off equipment, disconnect power) and contact with escaping electrolyte (eye flush, gargle, wash skin).
Long Term Storage
Reconditioning procedure for capacitors stored for over one year (applying rated voltage in series with a 1000 resistor for 30 minutes). Products with date codes over eighteen months require confirmation.
Capacitor Disposal
Recommended disposal methods include incineration after crushing or puncturing, or disposal as solid waste, adhering to local laws. Incineration at high temperatures is advised to prevent toxic gas release.
2411272157_Man-Yue-Tech-ERD225M2WF12RR_C2903600.pdf