Product Overview
The SAMXON RT Series Aluminum Electrolytic Capacitors are polar, foil-type capacitors designed for use in electronic equipment. These capacitors meet IEC60384 standards and are constructed with a single-ended design, featuring an aluminum case impregnated with electrolyte and enclosed in a vinyl sleeve. They are suitable for a wide range of applications requiring reliable performance and specific electrical characteristics.
Product Attributes
- Brand: SAMXON
- Series: RT Series
- Construction Type: Single ended, foil type
- Sleeve Material: PET
- Sealing Material: Rubber
- Lead Material: Tinned CP wire (Pb Free)
Technical Specifications
| SAMXON Part No. | WV (Vdc) | Cap. (F) | Cap. tolerance | Temp. range() | tan (120Hz, 20) | Leakage Current (A, 2min) | Max Ripple Current at 105 (mA rms) | Load lifetime (Hrs) | Dimension (mm) DL | F (mm) | d (mm) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ERT106M2WG16RR**P | 450 | 10 | -20%~+20% | -25~105 | 0.20 | 115 | 360 | 5000 | 10X16 | 5.0 | 0.6 |
General Characteristics
- Rated Voltage (WV): 160, 200, 220, 250, 350, 400, 420, 450 V.DC
- Surge Voltage (SV): 200, 250, 270, 300, 400, 450, 470, 500 V.DC
- Capacitance Measurement Conditions: Frequency: 120Hz12Hz, Voltage: 0.5Vrms, Temperature: 202
- Leakage Current Measurement: Measured after connecting with a protective resistor (1k 10) in series for 2 minutes.
- Terminal Strength: Tensile force: 5-10 N (0.51-1.0 kgf), Bending force: 2.5-5 N (0.25-0.51 kgf) depending on diameter.
- Load Life Test: 105C 2 with DC bias voltage plus rated ripple current for specified duration.
- Shelf Life Test: Stored at 1052 for 1000+48/0 hours without voltage.
- Surge Test: 1000 cycles of charge (305s) and discharge (5 min 30s) with surge voltage.
- Vibration Test: 10Hz ~ 55Hz, 1.5mm peak to peak amplitude for 2 hours in each of 3 directions.
- Solderability Test: Soldering temperature: 2453, Dipping depth: 2mm, Dipping speed: 252.5mm/s, Dipping time: 30.5s.
- Resistance to Solder Heat: Immersion into solder bath at 2605 for 101s or 40010 for 3+0-1s.
- Change of Temperature Test: 5 cycles of temperature changes between +20, rated low temperature (-40 or -25), and +105.
- Damp Heat Test: 5008 hours in 90~95% RH at 402.
- Vent Test: For products with vents (diameter 6.3mm), tested with reversed DC polarity and applied current.
- Maximum Permissible Ripple Current: Maximum AC current at 100kHz and maximum operating temperature.
Application Guidelines
When designing circuits, consider the effects of operating temperature and frequency on electrical parameters. Avoid misapplication conditions such as reverse voltage, charge/discharge applications, overvoltage, and excessive ripple current. When using capacitors in series or parallel, ensure proper voltage or current balancing. Pay attention to capacitor mounting considerations including circuit board design, hole positioning, and clearance for pressure relief vents. Ensure electrical isolation of the capacitor. Handle capacitors with care, verify polarity before insertion, and follow proper soldering techniques. Circuit board cleaning requires appropriate solvents and drying procedures. Avoid using capacitors in environments exceeding rated temperature limits or exposed to water, corrosive gases, or excessive vibration.
Capacitor Handling Techniques
Handle capacitors with care to avoid mechanical or electrical damage. Verify correct capacitance and rated voltage before use. Ensure correct polarity before insertion. Avoid stressing terminals during insertion and soldering. Follow specified soldering temperatures and times. After soldering, avoid moving the capacitor to prevent stress on lead wires. Use appropriate cleaning solvents and drying procedures. Avoid using capacitors in environments exceeding rated temperature limits or exposed to water, corrosive gases, or excessive vibration.
Emergency Procedures
If the pressure relief vent operates, immediately turn off equipment and disconnect from power. Avoid contact with escaping electrolyte gas. In case of contact, flush eyes with water, gargle with water if ingested, and wash skin with soap and water.
Long Term Storage
Leakage current may increase with long storage times. Recondition capacitors stored for over one year by applying rated voltage in series with a 1000 current limiting resistor for 30 minutes. Products with date codes over eighteen months should be returned for confirmation.
Capacitor Disposal
Dispose of capacitors by incineration after crushing or puncturing, or as solid waste, following local laws and regulations.