Specifications
Operating Temperature:
-45℃~+105℃
Lifetime:
7000hrs@105℃
Capacitance:
100uF
Height - Seated (Max):
16mm
Pin Spacing:
5mm
Voltage Rating:
100V
Diameter:
10mm
Equivalent Series Resistance(ESR):
-
Tolerance:
±20%
Ripple Current:
-
Mfr. Part #:
EGT107M2AG16RR
Package:
Through Hole,D10xL16mm
Key Attributes
Model Number: EGT107M2AG16RR
Product Description

Product Overview

The SAMXON GT Series Aluminum Electrolytic Capacitors are polar, foil-type capacitors designed for use in electronic equipment. These capacitors meet IEC60384 standards and are constructed with a single-ended, wound element impregnated with electrolyte, enclosed in an aluminum case and sealed with end seal rubber, finished with a PET vinyl sleeve. They are suitable for general electronic applications requiring stable performance across a wide temperature range.

Product Attributes

  • Brand: SAMXON
  • Series: GT Series
  • Construction Type: Single ended, foil type
  • Sleeve Material: PET
  • Compliance: Meets IEC60384 standards

Technical Specifications

SAMXON Part No. WV (Vdc) Cap. (F) Cap tolerance Temp. range() tan (120Hz, 20) Leakage Current (A, 2min) Max Ripple Current at 105 100KHz (mA rms) Impedance at 20 100kHz (max) Load lifetime (Hrs) Dimension (mm) DL F d Sleeve
EGT107M2AG16RR**P-R 100 100 -20%~+20% -40~105 0.08 100 357 0.248 7000 10X16 5.0 0.6 PET

General Characteristics

Item Description
Standard atmospheric conditions Ambient temperature: 15C to 35C, Relative humidity: 45% to 85%, Air Pressure: 86kPa to 106kPa. For critical measurements: Ambient temperature: 20C 2C, Relative humidity: 60% to 70%, Air Pressure: 86kPa to 106kPa.
Operating temperature range Refer to Table 1 (Temperature range: -40~105).
Rated voltage (WV) 6.3, 10, 16, 25, 35, 50, 63, 100 V.DC
Surge voltage (SV) 8, 13, 20, 32, 44, 63, 79, 125 V.DC (corresponding to WV)
Nominal capacitance (Tolerance) Measured at 120Hz 12Hz, 0.5Vrms, 202. Shall be within specified capacitance tolerance.
Leakage current Measured after 2 minutes with a 1k 10 protective resistor. Refer to Table 1.
tan Measured at 120Hz 12Hz, 0.5Vrms, 202. Refer to Table 1.
Terminal strength Tensile force: 5N (0.51kgf) for 0.5mm wire, 10N (1.0kgf) for > 0.5mm to 0.8mm wire. Bending force: 2.5N (0.25kgf) for 0.5mm wire, 5N (0.51kgf) for > 0.5mm to 0.8mm wire. No breakage or looseness.
Load life test 105C 2C, DC bias + ripple current, for specified duration. Criteria: Leakage current within 4.3, Capacitance change 25%, tan 200% of specified value, no electrolyte leakage.
Shelf life test Stored at 1052 for 1000+48/0 hours. Criteria: Leakage current within 4.3, Capacitance change 25%, tan 200% of specified value, no electrolyte leakage.
Surge test 1000 cycles of charge (305s) and discharge (5 min 30s) with surge voltage. Criteria: Leakage current within specified value, Capacitance change 15%, tan within specified value, no electrolyte leakage.
Vibration test 10Hz ~ 55Hz, 1.5mm peak to peak amplitude for 2 hours in 3 directions. Criteria: No intermittent contacts, open/short circuit, no damage to terminals or electrodes, no mechanical damage, no electrolyte leakage.
Solderability test 2503, 2mm dipping depth, 252.5mm/s dipping speed, 30.5s dipping time. Criteria: Minimum 95% of immersed surface coated.
Resistance to solder heat test 2605 for 101 seconds or 40010 for 3+0/-1 seconds, 1.5~2.0mm from body. Criteria: Leakage current within specified value, Capacitance change 10%, tan within specified value, no electrolyte leakage.
Change of temperature test 5 cycles of -40 (-25) / +105 for 302 minutes each. Criteria: Leakage current within specified value, tan within specified value, no electrolyte leakage.
Damp heat test 90~95% RH at 402 for 5008 hours. Criteria: Leakage current within specified value, Capacitance change 20%, tan 120% of specified value, no electrolyte leakage.
Vent test Applies to products with vent (6.3). DC test with reversed polarity. Criteria: Vent operates with no dangerous conditions.
Maximum permissible (ripple current) Maximum AC current at 120Hz and maximum operating temperature. Frequency multipliers provided.

Environment-related Substances

Refer to the latest document of Environment-related Substances standard (WI-HSPM-QA-072). Controlled substances include heavy metals (Cadmium, Lead, Mercury, Hexavalent chromium), chlorinated organic compounds (PCB, PCN, PCT, SCCP), brominated organic compounds (PBB, PBDE), TBT, TPT, Asbestos, specific azo compounds, formaldehyde, beryllium oxide, beryllium copper, specific phthalates, HFC, PFC, PFOS, and specific Benzotriazole.

Application Guidelines

Circuit Design: Electrical parameters vary with temperature and frequency. Consider effects on leakage current, capacitance, and ESR. Avoid reverse voltage, repeating charge/discharge, over voltage, and excessive ripple current. For series/parallel connections, consider voltage and current balancing. Mounting considerations include avoiding shorts on double-sided boards, proper hole spacing, clearance for pressure relief vents, and avoiding high voltage/current wiring near vents. Ensure electrical isolation. Product endurance should be based on samples. Collect date code within 6 months for load/shelf life tests. The vinyl sleeve is for identification and not for insulation.

Capacitor Handling Techniques: Do not reuse capacitors from used equipment. Discharge transient recovery voltage if necessary. Recondition capacitors stored for long periods by applying rated voltage with a current-limiting resistor. Avoid using dropped, dented, or crushed capacitors. Verify capacitance, rated voltage, and polarity before insertion. Ensure auto insertion equipment does not stress leads. Observe soldering temperature and time specifications, avoid stressing leads during formation or reinsertion, and do not touch the capacitor body with a soldering iron. For flow soldering, do not immerse the capacitor body. Avoid rapid temperature rises during preheating and resin bonding. Avoid movement after soldering to prevent stress on leads. Do not use capacitors as handles. Avoid striking capacitors after assembly. Circuit board cleaning requires suitable solvents, rinsing, and thorough drying. Avoid ozone-depleting, halogenated, alkali, petroleum-based, xylene, or acetone solvents unless specified. Monitor contamination levels. When using mounting adhesives or coating agents, avoid halogenated solvents and chloroprene-based polymers.

Precautions for using capacitors: Do not store or use capacitors outside rated temperature ranges, in contact with water/salt water/oil, high humidity, toxic gases, ozone, radiation, or excessive vibration/shock. Avoid touching terminals due to electric shock risk. Do not short circuit terminals. In case of pressure relief vent operation, immediately turn off equipment. Avoid contact with escaping electrolyte gas. Follow first aid procedures for eye/mouth/skin contact. For long-term storage (over one year), recondition capacitors by applying rated voltage in series with a 1000 resistor for 30 minutes. Products over eighteen months should be returned for confirmation.

Capacitor Disposal: Incinerate after crushing or puncturing the can wall to prevent explosion. Incinerate at high temperatures to prevent toxic gas release. Dispose of as solid waste, following local laws.