Product Overview
SAMXON SK Series Aluminum Electrolytic Capacitors are designed for general electronic equipment applications. These polar, foil-type capacitors meet IEC60384 standards and are constructed with tinned CP wire leads, aluminum foil, electrolyte paper, and an aluminum case sealed with rubber and a PET sleeve. They are suitable for applications requiring reliable performance across a specified temperature range and voltage rating.
Product Attributes
- Brand: SAMXON
- Category: ALUMINUM ELECTROLYTIC CAPACITORS
- Construction Type: Single ended
- Sleeve Material: PET
- Origin: MAN YUE ELECTRONICS COMPANY LIMITED
Technical Specifications
Model: SK Series
| SAMXON Part No. | WV (Vdc) | Cap. (F) | Cap. tolerance | Temp. range () | tan (120Hz ,20) | Leakage Current (A,2min) | Max Ripple Current at 105 100kHz (mA rms) | Impedance at 20 100KHz (max) | Load lifetime (Hrs) | Dimension (mm) DL | F (mm) | d (mm) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ESK227M2AI20RR**P-R | 100 | 220 | -20%~+20% | -40~105 | 0.08 | 220 | 1750 | 0.062 | 10000 | 12.5X20 | 5.0 | 0.6 |
Performance Characteristics
Standard Atmospheric Conditions: Ambient temperature: 15C to 35C, Relative humidity: 45% to 85%, Air Pressure: 86kPa to 106kPa. For doubt, measurements within: Ambient temperature: 20C 2C, Relative humidity: 60% to 70%, Air Pressure: 86kPa to 106kPa.
Rated Voltage (WV): 100 Vdc
Surge Voltage (SV): 125 Vdc
Nominal Capacitance Measurement: 120Hz12Hz, 0.5Vrms, 202
Leakage Current Measurement: Connected with a protective resistor (1K 10) in series for 2 minutes.
tan Measurement: 120Hz, 202
Impedance Measurement: 100kHz, 202, 2mm max. from sealing rubber.
Terminal Strength: Tensile force (0.5mm and less: 5N, Over 0.5mm to 0.8mm: 10N), Bending force (0.5mm and less: 2.5N, Over 0.5mm to 0.8mm: 5N).
Load Life Test: 105C 2, DC bias voltage plus rated ripple current for Table 1. Duration: 10000 Hrs.
Shelf Life Test: 1052 for 1000+48/0 hours.
Surge Test: 1000 cycles of 30s charge and 5 min 30s discharge at 15~35.
Vibration Test: 10Hz ~ 55Hz, 1.5mm peak to peak amplitude for 2 hours in 3 directions.
Solderability Test: 2453, 2mm dipping depth, 252.5mm/s, 30.5s.
Resistance to Solder Heat Test: 2605 for 101 seconds or 40010 for 10.1 seconds.
Change of Temperature Test: 5 cycles of 20, -25 (302 min), +105 (302 min).
Damp Heat Test: 90~95% RH at 402 for 5008 hours.
Vent Test: For products with vent 6.3. DC test with reversed polarity; vent operates with no dangerous conditions.
Maximum Permissible Ripple Current: At 100kHz, 105. Frequency multipliers provided for different frequencies and capacitance values.
Environment-related Substances
Refer to the latest document of Environment-related Substances standard (WI-HSPM-QA-072) for controlled substances including Heavy metals, Hexavalent chromium compounds, Chlorinated organic compounds, Brominated organic compounds, etc.
Application Guidelines
Circuit Design: Electrical parameters vary with temperature and frequency. Consider effects on leakage current, capacitance, and ESR. Avoid reverse voltage, repeating charge/discharge, over voltage, and exceeding maximum ripple current. Use appropriate wiring for parallel/series capacitor configurations. Ensure proper mounting clearances for pressure relief vents and avoid routing sensitive wiring near vents. For screw terminal capacitors, do not orient with the terminal side facing downwards.
Capacitor Handling: Verify capacitance, rated voltage, and polarity before insertion. Avoid mechanical stress on leads. Observe soldering temperature and time specifications. Avoid immersing the capacitor body into the solder bath. Do not use capacitors as a handle when moving circuit board assemblies. Clean circuit boards using suitable solvents, avoiding halogenated, alkali, petroleum-based, xylene, and acetone solvents unless specified. Ensure thorough drying after cleaning.
Precautions: Do not store or use capacitors outside rated temperature ranges, in contact with water/salt water/oil, high humidity, toxic gases, ozone, radiation, or exceeding vibration/shock requirements. Avoid touching terminals due to electric shock risk. Do not short circuit terminals with conductive materials.
Emergency Procedures: If vent operates, immediately turn off equipment. Avoid contact with escaping electrolyte gas. Flush eyes with water if contact occurs. Wash skin with soap and water.
Long Term Storage: Leakage current increases with storage time. Recondition capacitors stored for over one year by applying rated voltage in series with a 1000 resistor for 30 minutes. Products with date codes over eighteen months should be returned for confirmation.
Capacitor Disposal: Incinerate after crushing or puncturing to prevent explosion, or dispose of as solid waste, following local laws.
2410121541_Man-Yue-Tech-ESK227M2AI20RRSNP-R_C2798379.pdf