SAMXON RT Series Aluminum Electrolytic Capacitors
Product Overview
The SAMXON RT Series Aluminum Electrolytic Capacitors are polar, foil-type capacitors designed for use in electronic equipment. Meeting IEC60384 standards, these capacitors are constructed with an aluminum case, end seal rubber, and a vinyl sleeve. They are suitable for general electronic equipment applications where reliable performance is required.
Product Attributes
- Brand: SAMXON
- Series: RT Series
- Type: Polar Aluminum Electrolytic Capacitor (foil type)
- Construction: Single ended type, impregnated with electrolyte, enclosed in an aluminum case, sealed with end seal rubber, and finished with a vinyl sleeve.
- Compliance: Designed to meet IEC60384 standards.
- Materials: Lead line: Tinned CP wire (Pb Free); Terminal: Aluminum wire; Sealing Material: Rubber; Case: Aluminum; Sleeve: PET; Separator: Electrolyte paper.
Technical Specifications
| SAMXON Part No. | WV (Vdc) | Cap. (F) | Cap. tolerance | Temp. range() | tan (120Hz, 20) | Leakage Current (A, 2min) | Max Ripple Current at 105 100KHz (mA rms) | Load lifetime (Hrs) | Dimension (mm) DL | F | d |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ERT226M2WI16RR**R | 450 | 22 | -20%~+20% | -25~+105 | 0.20 | 223 | 580 | 5000 | 12.5X16 | 5.0 | 0.6 |
General Characteristics
- Standard Atmospheric Conditions: Ambient temperature: 15 to 35, Relative humidity: 45% to 85%, Air Pressure: 86kPa to 106kPa.
- Measurement Conditions: Ambient temperature: 20 2, Relative humidity: 60% to 70%, Air Pressure: 86kPa to 106kPa.
- Rated Voltage (WV) & Surge Voltage (SV) Examples:
- WV: 160-450 V.DC
- SV: 200-500 V.DC - Nominal Capacitance: Measured at 120Hz 12Hz, 0.5Vrms, 202.
- Leakage Current: Measured after 2 minutes with a 1k 10 protective resistor. Refer to Table 1 for values.
- tan: Measured under the same conditions as nominal capacitance. Refer to Table 1 for values.
- Terminal Strength: Specified tensile and bending forces based on lead wire diameter.
- Load Life Test: Tested at 105C 2 with DC bias voltage plus rated ripple current for specified duration. Criteria include limits on leakage current, capacitance change (20%), tan (200% of specified value), and no electrolyte leakage.
- Shelf Life Test: Stored at 1052 for 1000+48/0 hours. Criteria include limits on leakage current, capacitance change (20%), tan (200% of specified value), and no electrolyte leakage.
- Surge Test: 1000 cycles of charge (305s) and discharge (5 min 30s) with a surge voltage. Criteria include limits on leakage current, capacitance change (15%), tan, and no electrolyte leakage.
- Vibration Test: 10Hz ~ 55Hz, 1.5mm peak to peak amplitude for 2 hours in 3 directions. Criteria include no intermittent contacts, open/short circuits, or damage.
- Solderability Test: Soldering temperature 2453, dipping depth 2mm, dipping speed 252.5mm/s, dipping time 30.5s. Minimum 95% surface coverage required.
- Resistance to Solder Heat Test: Immersed in solder bath at 2605 for 101 seconds or 40010 for 3+0-1 seconds. Criteria include limits on leakage current, capacitance change (10%), tan, and no electrolyte leakage.
- Change of Temperature Test: 5 cycles of temperature changes (-40/-25 to +105). Criteria include limits on leakage current, tan, and no electrolyte leakage.
- Damp Heat Test: 5008 hours at 402, 90~95% RH. Criteria include limits on leakage current, capacitance change (20%), tan (120% of specified value), and no electrolyte leakage.
- Vent Test: For products with vent ( 6.3). DC test with reversed polarity. Criteria include vent operation with no dangerous conditions.
- Maximum Permissible Ripple Current: Maximum AC current at 120Hz and maximum operating temperature. Frequency and temperature multipliers provided.
Environment-related Substances to be Controlled
Refers to the latest document of Environment-related Substances standard (WI-HSPM-QA-072). Lists controlled substances including heavy metals, chlorinated organic compounds, brominated organic compounds, etc.
Attachment: Application Guidelines
Provides guidance on circuit design, handling techniques, and precautions for using capacitors, including considerations for operating temperature, frequency, reverse voltage, over voltage, ripple current, series/parallel connections, mounting, cleaning, and disposal.
2410121611_Man-Yue-Tech-ERT226M2WI16RR_C2903656.pdf