X-CON BRAND CONDUCTIVE POLYMER ALUMINUM SOLID CAPACITORS
This specification applies to conductive polymer aluminum solid capacitors used in electronic equipment. These capacitors offer advanced performance characteristics suitable for various electronic applications.
Product Attributes
- Brand: X-CON
- Category: CONDUCTIVE POLYMER ALUMINUM SOLID CAPACITORS
- Model: ULR 2.5V820uF (8X8)
- Series: ULR
- Construction: Single ended type, aluminum case, sealed with end seal rubber.
- Materials: Tinned Copper Line or CP Line (Pb Free) for Lead Line, Aluminum for Terminal, Al-Foil, and Case, Rubber for Sealing Material, Manila Hemp for Electrolyte paper.
- Date of Issue: 2021-05-12
- Version: 01
Technical Specifications
| Rated Voltage (WV) (V.DC) | Surge Voltage (SV) (V.DC) | Nominal Capacitance (F) | Capacitance Tolerance | Rated Voltage Code | Diameter Code | Case Length (mm) | Type Code | Max. tan (at 2.5V) | ESR (20) | Operating Temperature Range (C) | Load Life Test (at 105C) | Damp Heat Test (90~95%RH, 60C) | Max. Permissible Ripple Current (at 100kHz) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2.5 | 2.87 | 820 | -20% ~ +20% | 0E | F (8mm) | 08 | RR (Bulk) | 0.10 | < Initial Limit (See Table 3) | -55 to 105 | 2000+48/0 hours @ Rated Voltage | 100048 hours @ 90~95%RH, 602C | See Table 3 |
Performance Criteria (Post-Test)
| Test Type | Capacitance Change | tan | ESR | Leakage Current | Appearance |
|---|---|---|---|---|---|
| Load Life Test | Within 20% of initial | 1.5 x initial | 1.5 x initial | Initial Value | No notable changes |
| Surge Test | Within 20% of initial | 1.5 x initial | 1.5 x initial | Initial Value | N/A |
| Damp Heat Test | Within 20% of initial | 1.5 x initial | 1.5 x initial | Initial Value | No notable changes |
| Rapid Change of Temperature | Within 10% of initial | Initial Value | N/A | Initial Value (after voltage treatment) | N/A |
| Lead Strength (Pull & Bending) | N/A | N/A | N/A | Initial Value | No cutting and slack of lead terminals |
| Resistance to Vibration | Within 5% of initial (after exam) | N/A | N/A | N/A | N/A |
Additional Information
Standard Atmospheric Conditions for Measurement: Ambient temperature: 15C to 35C, Relative humidity: 45% to 75%, Air Pressure: 86kPa to 106kPa.
Conditions for Verification: Ambient temperature: 20C 2C, Relative humidity: 60% to 70%, Air Pressure: 86kPa to 106kPa.
Application Guideline: Includes sections on circuit design, voltage, sudden charge and discharge, ripple current, leakage current, failure rate, capacitor insulation, and general precautions for using capacitors.
Mounting Precautions: Detailed in section 8.
Controlled Substances: List of "Environment-related Substances to be Controlled" is provided in section 9.