Product Overview
This specification sheet details the K26160002020 Quartz Crystal Resonator from Kaiyuexiang Electronics Co., Ltd. It is designed for applications requiring precise frequency control, featuring a nominal frequency of 16.000 MHz and tight frequency tolerance.
Product Attributes
- Brand: Kaiyuexiang ()
- Origin: Shenzhen, China
- Product Name: Quartz Crystal Resonator ()
- Product Model: 2*6/16.000MHZ
- Original Factory Model: K26160002020
Technical Specifications
| Parameter | Specification | Conditions |
|---|---|---|
| Case Type | 26 | |
| Vibration Mode | Fundamental | |
| Nominal Frequency | 16.000 MHz | |
| Frequency Tolerance | 20ppm | at 252 |
| Temperature Frequency Drift | 20ppm | |
| Load Capacitance | 20 PF | |
| Resonant Resistance | 60 max | |
| Shunt Capacitance | 3.0pF max | |
| Drive Level | 100W | |
| Aging Rate | 3ppmyear | |
| Insulation Resistance | 500M min | DC10015V |
| Test Instrument | 250B | |
| Free Fall (Shock) | Frequency deviation 5ppm after 3 drops from 35cm height onto 2cm thick board | |
| Vibration | Frequency change 20ppm | 10~55Hz, 0.75mm amplitude, 30 min each in X, Y, Z directions |
| Temperature Cycling | Appearance no damage, performance same as vibration test | 3 cycles: -10 (2-3min) +60 (30min) Room Temp (30min) |
| Solderability | Tinned area >95% | 20.5 sec in 2355 solder bath (2-3.0mm from lead end). Performance same as vibration test. |
| Resistance to Soldering Heat | Appearance no abnormality, performance same as vibration test | 3.50.5 sec in 250 10 solder bath (2-2.5mm from lead end). |
| Low Temperature Resistance | Performance same as vibration test | 2 hours at -253, then 2 hours recovery at room temperature. |
| High Temperature Resistance | Performance same as vibration test | 2 hours at +702, then 2 hours recovery at room temperature. |
| Constant Damp Heat | Appearance no abnormality, performance same as vibration test | 48 hours at 403, RH932, then 2 hours recovery. |
| High Temperature Aging | Frequency change 5ppm, Resistance change 25 | 48 hours at 1202, then 2 hours recovery at room temperature. |
2310101743_KYX-K26160002020_C18208993.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible