Specifications
Normal temperature Frequency Tolerance:
±20ppm
Frequency Stability:
±20ppm
Operating Temperature:
-20℃~+70℃
Load Capacitance:
20pF
Equivalent Series Resistance(ESR):
40Ω
Frequency:
27MHz
Mfr. Part #:
K26270002020
Package:
DT-26
Key Attributes
Model Number:
K26270002020
Product Description
Product Overview
The KAIYUE Xiang Quartz Crystal Resonator is a high-frequency electronic component designed for precise oscillation. It is suitable for various electronic applications requiring stable frequency output.
Product Attributes
- Brand: (KAIYUE Xiang)
- Product Name: (Quartz Crystal Resonator)
- Product Model: 2*6/27.000 MHZ
- Original Factory Model: K26270002020
- Manufacturer: (Shenzhen Kaiyue Xiang Industrial)
- Factory Address: (4th Floor, Building 1, Caifa Industrial City, Renmin Road, Guanlan, Bao'an District, Shenzhen)
- Contact: TEL: 0755-89315823 / 89315866, FAX: 0755-89315223
- Website: www.kaiyuexiang.com
Technical Specifications
| Parameter | Value |
|---|---|
| Box Type | 26 |
| Vibration Mode | Fundamental Frequency |
| Nominal Frequency | 27.000 MHz |
| Frequency Tolerance (at 202) | 20ppm |
| Temperature Frequency Tolerance | 20PPM |
| Load Capacitance | 20 PF |
| Resonant Resistance | 60 max |
| Static Capacitance | 7.0pF max |
| Drive Level | 100W |
| Aging Rate (per year) | 5ppmyear |
| Insulation Resistance | 500M (DC10015V) |
| Test Instrument | 250B |
| Free Fall (Shock) | Drop 3 times from 35cm height onto 2cm thick board. Frequency deviation after drop 5ppm. |
| Vibration | 10~55Hz, 0.75mm amplitude, 30 minutes in X, Y, Z directions. Frequency variation 20ppm. |
| Temperature Cycling | -10 (2-3min) +60 (30min). Repeat 3 times. No visual damage. Performance test requirements same as Vibration. |
| Solderability | Immerse 2~3.0mm from lead end in 2355 solder bath for 20.5 seconds. Tinned area >95%. Performance test requirements same as Vibration. |
| Resistance to Soldering Heat | Immerse 2~2.5mm from lead end in 250 10 solder bath for 3.50.5 seconds. No visual abnormality after test. Performance test requirements same as Vibration. |
| Low Temperature Resistance | Place at -253 for 2 hours, then recover at room temperature for 2 hours. Performance test same as Vibration. |
| High Temperature Resistance | Place at +702 for 2 hours, then recover at room temperature for 2 hours. Performance test same as Vibration. |
| Constant Humidity Heat | Place at 403, RH932 for 48 hours, then recover for 2 hours. No visual abnormality. Performance test requirements same as Vibration. |
| High Temperature Aging | Age at 1202 for 48 hours, then recover at room temperature for 2 hours. Frequency variation 5ppm, Resistance variation 25. |
1912111437_KYX-K26270002020_C368793.pdf
Request A Quote
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible