Specifications
Normal temperature Frequency Tolerance:
±20ppm
Frequency Stability:
±20ppm
Operating Temperature:
-20℃~+70℃
Load Capacitance:
20pF
Equivalent Series Resistance(ESR):
40Ω
Frequency:
24MHz
Mfr. Part #:
K26240002020
Package:
DT-26
Key Attributes
Model Number:
K26240002020
Product Description
Product Overview
This document specifies the technical details for the Kaiyuexiang Quartz Crystal Resonator, model 2*6/24.000 MHZ. It is designed for applications requiring precise frequency control.
Product Attributes
- Brand: Kaiyuexiang
- Original Model: K26240002020
- Manufacturer:
- Factory Address:
- Website: www.kaiyuexiang.com
Technical Specifications
| Item | Specification |
| Case Type | 26 |
| Vibration Mode | Fundamental |
| Nominal Frequency | 24.000 MHz |
| Frequency Tolerance (at 202) | 20ppm |
| Temperature Frequency Difference | 20PPM |
| Load Capacitance | 20 PF |
| Resonant Resistance | 60 max |
| Shunt Capacitance | 7.0pF max |
| Drive Level | 100W |
| Aging Rate (per year) | 5ppmyear |
| Insulation Resistance | 500MDC10015V |
| Test Instrument | 250B |
| Free Fall (Shock) | 35cm height to 2cm thick wood board, 3 drops. Frequency deviation 5ppm after drop. |
| Vibration | 10~55Hz, 0.75mm amplitude, 30 min each in X, Y, Z directions. Frequency variation 20ppm. |
| Temperature Cycling | -10 to +60, 3 cycles (2-3min transition, 30min dwell). No visual damage. Performance requirements same as vibration. |
| Solderability | 2355 solder bath for 20.5 sec, 2~3.0mm from lead end. 95% tinned surface. Performance requirements same as vibration. |
| Resistance to Soldering Heat | 250 10 solder bath for 3.50.5 sec, 2~2.5mm from lead end. No visual abnormalities. Performance requirements same as vibration. |
| Low Temperature Resistance | -253 for 2 hours, then 2 hours at room temperature recovery. Performance requirements same as vibration. |
| High Temperature Resistance | +702 for 2 hours, then 2 hours at room temperature recovery. Performance requirements same as vibration. |
| Constant Damp Heat | 403, RH932 for 48 hours, then 2 hours recovery. No visual abnormalities. Performance requirements same as vibration. |
| High Temperature Aging | 1202 for 48 hours, then 2 hours room temperature recovery. Frequency variation 5ppm, resistance variation 25. |
1912111437_KYX-K26240002020_C368791.pdf
Request A Quote
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible