Product Overview
This datasheet specifies the Kaiyuexiang Quartz Crystal Resonator, model 2016/48.000MHZ. It is designed for applications requiring precise frequency control with a frequency tolerance of 10ppm at 253 and a load capacitance of 8 PF. The resonator operates within a temperature range of -40 to +85 and features a fundamental mode of oscillation.
Product Attributes
- Brand: Kaiyuexiang
- Origin: Shenzhen, China
- Product Name: Quartz Crystal Resonator
- Original Model Number: K2B480000810
- Marking Description: KYX48.000
Technical Specifications
| Parameter | Specification | Unit | Condition |
|---|---|---|---|
| Frequency | 48.000 | MHz | |
| Holder Type | SMD2.0*1.6 | ||
| Frequency Tolerance | 10 | ppm | at 253 |
| Equivalent Series Resistance | 40 | Max | |
| Storage Temperature Range | -40 to +85 | ||
| Operating Temperature Range | -40 to +85 | ||
| Frequency Characteristics Over Temperature | 20 | ppm | -40+85 |
| Load Capacitance (CL) | 8 | PF | |
| Drive Level | 100 | W | |
| Shunt Capacitance | 5 | PF | MAX |
| Insulation Resistance | 500 | M | Min at 100 V |
| Mode Of Oscillation | Fundamental | ||
| Aging | 3 | ppm/Year | |
Reliability Testing
| Test Item | Test Conditions and Requirements | Requirement |
|---|---|---|
| Vibration | Frequency sweep from 10Hz to 50Hz and return to 10Hz at 1min/octave. Amplitude: 1.5mm. Applied for 2h each of 3 mutually perpendicular axes (total 6h). | (1).FL:+/-10ppm (2).Rr:+/-10 |
| Drop | From 70cm height onto 3cm hard wooden floor, 3 times. | |
| Shock | Peak acceleration: 981m/s. Duration: 6ms. Three successive shocks applied in both directions of 3 mutually perpendicular axes (total 18 shocks). | (1).FL:+/-10ppm (2).Rr:+/-10 |
| Damp Heat, Constant | Stored at 402 with 90%-95% RH for 48h, then subjected to standard atmospheric conditions for 1-2h before measurement. | |
| Cold Storage | Stored at -405 for 48h, then subjected to standard atmospheric conditions for 1-2h before measurement. | |
| Dry Heat Storage | Stored at 1005 for 24h, then subjected to standard atmospheric conditions for 1-2h before measurement. | |
| Aging | Stored at 855 for 7 days, then subjected to standard atmospheric conditions for 1-2h before measurement. | |
| Temperature Cycling | 5 successive cycles as per table below, then subjected to standard atmospheric conditions for 1-2h before measurement. |
| Cycle Step | Temperature | Duration |
|---|---|---|
| 1 | -403 | 30min |
| 2 | Standard atmospheric conditions | Within 30s |
| 3 | 1003 | 30min |
| 4 | Standard atmospheric conditions | Within 30s |
| Test Item | Test Conditions and Requirements | Requirement |
|---|---|---|
| Resistance to Soldering Heat |