Quartz Crystal Resonator Specification
This specification document, along with this page, comprises 6 pages. The product is a Quartz Crystal Resonator, model 3225/16.000MHZ, with parameters 20PF/10ppm. The original manufacturer model is K3A160002010.
Product Attributes
- Brand: (Kaiyuexiang Industrial)
- Factory Address:
- Telephone: 0755-89315823, 89315866
- Fax: 0755-89315223
- Website: www.kaiyuexiang.com
Technical Specifications
| Parameter | Value | Unit | Condition |
|---|---|---|---|
| Frequency | 16.000 | MHZ | |
| Holder Type | SMD3.2*2.5 | ||
| Frequency Tolerance | 10 | ppm | at 253 |
| Equivalent Series Resistance | 40 | Max | |
| Storage Temperature Range | -40 to +85 | ||
| Operating Temperature Range | -40 to +85 | ||
| Frequency Characteristics Over Temperature | 10 | ppm | -40+85 |
| Load Capacitance (CL) | 20 | PF | |
| Drive Level | 100 | W | Max |
| Shunt Capacitance | 3 | PF | MAX |
| Insulation Resistance | 500 | M | Min at 100 V |
| Mode Of Oscillation | Fundamental | ||
| Aging | 3 | ppm/Year | |
| Marking Description | K16.00 MHZ |
Reliability Testing
| Test Item | Conditions and Requirements |
|---|---|
| Vibration | Frequency sweep from 10Hz to 55Hz and return to 10Hz at 1 octave/min. Amplitude: 1.5mm. Applied for 2h each in 3 mutually perpendicular axes (total 6h). |
| Drop | From 70cm height onto 3cm hard wooden floor, 3 times. Results: (1).FL:+/-5ppm (2).Rr:+/-15%. |
| Shock | Peak acceleration: 981m/s. Pulse duration: 6ms. Three successive shocks applied in both directions of 3 mutually perpendicular axes (total 18 shocks). |
| Damp Heat, Constant | Stored at 402 with 90%-95% RH for 48h, then subjected to standard atmospheric conditions for 1-2h before measurement. |
| Cold Storage | Stored at -405 for 48h, then subjected to standard atmospheric conditions for 1-2h before measurement. |
| Dry Heat Storage | Stored at 1005 for 24h, then subjected to standard atmospheric conditions for 1-2h before measurement. |
| Aging | Stored at 855 for 7 days, then subjected to standard atmospheric conditions for 1-2h before measurement. |
| Temperature Cycling | 5 successive cycles with parameters: -403 for 30min, Standard atmospheric conditions within 30s, 1003 for 30min, Standard atmospheric conditions within 30s. Subjected to standard atmospheric conditions for 1-2h after cycles. Results: (1).FL:+/-10ppm (2).Rr:+/-80. |
| Resistance to Soldering Heat | (Data not fully specified in text) |
Prepared by: , Reviewed by: , Approved by:
2410121237_KYX-K3A160002010_C368736.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible