Product Overview
The H2 Series Solid Electrolyte Aluminum Electrolytic Capacitor (E-CAP) by Hyncdz offers low ESR, high ripple current, and high voltage capabilities. Designed for a load life of 2000 hours at 105, these RoHS Compliant capacitors are suitable for a wide range of applications requiring reliable performance in demanding conditions.
Product Attributes
- Brand: Hyncdz
- Series: H2 Series
- Type: (Lead Pin Type)
- Certifications: RoHS Compliant
- Color: (Red)
Technical Specifications
| Series | Capacitance (F) | Capacitance Tolerance (%) | Rated Voltage (VDC) | Surge Voltage (VDC) | Dissipation Factor (tan) Max. (120Hz/+20) | Leakage Current Max. (2min/+20, A) | ESR Max. (100KHz/+20, m) | Ripple Current Max. (100KHz, mArms) | Load Life (Hrs) | Diameter (mm) | Length (mm) | Pitch (mm) | Wire Diameter (mm) |
| H2 | 100 | 20 | 35 | 40.3 | 0.12 | 350 | 50 | 1500 | 2000 | 6.3 | 8 | 2.5 | 0.6 |
Key Characteristics
- Category Temperature Range: -55 ~ +105
- Rated Voltage Range: 35 ~ 160V
- Low Temperature Characteristics: Z(-25)/Z(+20) 1.25 (100KHz), Z(-55)/Z(+20) 1.25 (Max. Impedance Ratio)
- Endurance: 2000 hours at 105 with rated voltage. Capacitance change 20%, D.F.(tan) 150% of specified value, ESR 150% of specified value, Leakage current specified value.
- Damp Heat (Steady State): 1000 hours at 60, 90%~95% RH with rated voltage. Capacitance change 20%, D.F.(tan) 150% of specified value, ESR 150% of specified value, Leakage current specified value.
- Surge Voltage: Rated voltage 1.15(V)
Operating Precautions
- Polarity: Do not reverse polarity.
- Prohibited Circuits: Avoid high impedance, coupling, time constant, series connection for higher withstand voltage, and circuits sensitive to leakage current.
- Over Voltage: Do not exceed rated voltage.
- Sudden Charge and Discharge: Restricted. A protection circuit is recommended if rush current exceeds 10A or 10x allowable ripple current.
- Operating Temperature and Ripple Current: Exceeding limits can shorten life or increase leakage current.
- Leakage Current: May increase slightly due to soldering, but self-repairs with DC voltage.
- Applied Voltage: Recommended less than 80% of rated voltage. Peak DC and AC voltage should not exceed rated voltage.
Marking
- Series and trademark
- Capacitance
- Rated voltage
- Negative polarity
2410121438_HYNCDZ-H2101M035C080HY_C22447224.pdf