Product Overview
The RXM series wire-wound wafer resistors are non-flammable, coated resistors designed for applications such as chargers, energy-saving lamps, and power supplies. They are constructed with a wire wrapping on a matrix, insulated coating, and non-flame paint with solvent-proof markings. These resistors offer a wide operating temperature range and adhere to strict electrical and mechanical performance standards.
Product Attributes
- Brand: SHENZHEN XIANYANG HUAXING MACHINERG & ELECTRONIC.CO;LTD
- Origin: China
- Material: Nickel Chrome or nickel an copper alloy wire
- Coating: Non-flame paint with solvent-proof markings, Grey insulation paint
- Certifications: UL1412 standard
Technical Specifications
| Type | Series | Nominal Resistance Range | Tolerance | Rated Wattage | Operating Temperature Range | Dimensions (L x D) |
| Wire Wound Wafer Resistor | RXM | 1-100 | 1% (F), 2% (G), 5% (J) | 1/4W, 1/2W, 1W, 2W, 3W | -55275 | 0207: 6.1mm x 2.5mm 0309: 8.9mm x 3.4mm 0410: 10mm x 3.8mm 0411: 11mm x 4.6mm |
| Item | Specification | Test Method |
| Dielectric Strength Test | No evidence of flashover, mechanical damage or insulation breakdown. Resistance body placed in V-groove, use 300V voltage pressure 60 seconds. | JIS C5202 |
| Solder ability | 95% Surface of terminal covered by new solder. Immersed into tin stove at 27010 for 5s. | JIS C5202 |
| Resistance to soldering Heat | Within (1%+0.05). Immersed into tin stove at 2605 for 5~10s. | JIS C5202 |
| Short time over load | Within (2%+0.05). 2.5 Times rated voltage for 5s. | JIS C5202 |
| Load Life | Within (5%+0.05). 70 1000h Rated voltage (90 minutes ON, 30 minutes OFF). | JIS C5202 |
| Resistance to solvent | No deterioration of protective coating and markings. Add thinner in 3min. | JIS C5202 |
| Incombustibility | No evidence of flame. | UL1412 standard |
| Fusing characteristic | Fusing time is within 60s. Constant current 2.20A, Fusing current = 16 x P x R | JIS C5202 |
| Terminal Tensile Strength | Fixing the resistor body, a static load of 2.5Kg is to be gradually applied into the terminal for 10seconds without causing any looseness and fall. | Internal Standard |
2511041655_Huaxing-Mechanical-Elec--RXM0309-47RJ_C52268674.pdf