Product Overview
The GCNR8040 series from Shenzhen Glorious Electronic Co.,Ltd. is a line of magnetic components designed for various electronic applications. These components are manufactured using high-quality materials and undergo rigorous testing to ensure reliability and performance.
Product Attributes
- Brand: Glorious Electronic
- Origin: China
- Certifications: RoHS Compliant
- Color: Black printing (as indicated in Remarks)
Technical Specifications
| Type | Part NO. | Center Inductance Lo (uH) | Test Frequency (Hz/v) | DC Resistance (m) 30% | Saturation Current Isat (A) Max. L/L-35% | Temperature Rise Current Irms (A) Max. T40 |
| GCNR8040 | GCNR8040-2R2MC | 2.2 | 100KHz/1v | 12 | 7.10 | 5.15 |
| GCNR8040 | GCNR8040-3R3MC | 3.3 | 100KHz/1v | 17 | 6.50 | 4.40 |
| GCNR8040 | GCNR8040-4R7MC | 4.7 | 100KHz/1v | 20 | 5.90 | 4.10 |
| GCNR8040 | GCNR8040-5R6MC | 5.6 | 100KHz/1v | 24 | 5.50 | 3.85 |
| GCNR8040 | GCNR8040-6R8MC | 6.8 | 100KHz/1v | 28 | 4.55 | 3.60 |
| GCNR8040 | GCNR8040-100MC | 10 | 100KHz/1v | 34 | 3.80 | 3.30 |
| GCNR8040 | GCNR8040-150MC | 15 | 100KHz/1v | 56 | 2.95 | 2.60 |
| GCNR8040 | GCNR8040-220MC | 22 | 100KHz/1v | 74 | 2.40 | 2.10 |
| GCNR8040 | GCNR8040-330MC | 33 | 100KHz/1v | 100 | 2.05 | 1.80 |
| GCNR8040 | GCNR8040-470MC | 47 | 100KHz/1v | 158 | 1.75 | 1.55 |
| GCNR8040 | GCNR8040-680MC | 68 | 100KHz/1v | 196 | 1.45 | 1.25 |
| GCNR8040 | GCNR8040-101MC | 100 | 100KHz/1v | 295 | 1.15 | 1.00 |
| GCNR8040 | GCNR8040-151MC | 150 | 100KHz/1v | 470 | 1.10 | 0.85 |
| GCNR8040 | GCNR8040-221MC | 220 | 100KHz/1v | 660 | 0.85 | 0.80 |
| GCNR8040 | GCNR8040-331MC | 330 | 100KHz/1v | 970 | 0.68 | 0.64 |
| GCNR8040 | GCNR8040-471MC | 470 | 100KHz/1v | 1400 | 0.60 | 0.50 |
| Inductance Tolerance |
| J =5% |
| K =10% |
| L =15% |
| M = 20% |
| N=30% |
| Item | Specification | Condition |
| Terminal Strength | No electrode detachment should be found | When the device is pushed in two directions of X and Z with the force of 5N for 102seconds after soldering between copper plate and the electrodes |
| Reflow test | Change from an initial value L : within20% | Peak temp 2405 3010s. The specimen shall be subjected to the reflow process under the above condition 2 times. Test board shall be 0.8mm thick. Base material shall be glass epoxy resin. Measurement shall be stored at standard atmospheric conditions for 1 h in prior to the measurement. |
| Vibration | Change from an initial value L : within20% | The specimen shall be subjected to a vibration of 1.5mm amplitude, sweep frequency 10~55~10Hz after vibration for 1 hours |
| Free fall test | Change from an initial value L : within20% | The specimen must be fixed on test board. Then it shall be fallen freely from 1m height. 10 consecutive times. |
| High temperature and high humidity test | Change from an initial value L : within20% | The specimen shall be stored at a temperature of 402 with relative humidity of 90 ~ 95% for 96 4h. Then it shall be stabilized under standard atmospheric conditions for 1 h before measurement. Measurement shall be made within 1h~ 2h. |
| High temperature preservation test | Change from an initial value L : within20% | The specimen shall be stored at a temperature of 1252for 96 1h. Then it shall be stabilized under standard atmospheric conditions for 1 h before measurement. Measurement shall be made within 1h~ 2h. |
| Low temperature preservation test | Change from an initial value L : within20% | After stored at a temperature of -40 3 for 96 1h. The specimen should be measured, then it should be measured under normal temperature and humidity in 1h~ 2h hours. |
| Solder ability test | 95 | Terminals shall be immersed in flux at room temperature. Dip sample into solder bath containing molten solder at 2605for 30.5 seconds. |
| Cold and hot cycle test | Change from an initial value L : within20% | The specimen shall be measured after 20 continuous cycles of temperature change of -403for 30 min and 1252 for 30 min with the transit period of 2min or less. Then it shall be stabilized under standard atmospheric conditions for 1 h before measurement. Measurement shall be made within 1h~ 2h. |
| Storage temperature and humidity range | temperature range 535 humidity range 25%80% | In packing state. |
| Standard atmospheric conditions | Ambient temperature : 5to 35, Relative humidity: 45% to 85%, Air pressure: 86kPa to 106kPa. If more strict measurement is required, measurement shall be made within following limits; Ambient temperature : 202, Relative humidity: 655%, Air pressure: 86kPa to 106kPa | Unless otherwise specified. |
2410121507_GLE-GCNR8040-470MC_C439390.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible