ALUMINUM ELECTROLYTIC CAPACITORS
Econd KM Series aluminum electrolytic capacitors are designed for demanding applications. They are utilized in communication equipment, switching power supplies, and industrial measuring instruments. These capacitors offer a load life of 2000-3000 hours at 105 and comply with RoHS environmental requirements.
- Brand: Econd
- Series: KM
- Certifications: RoHS Compliant, JIS C-5141, JIS C-5102
Technical Specifications
| Item | Performance Characteristics | Range 1 | Range 2 |
| Operating Temp. Range | -40~+105 | -25~+105 | |
| Rated Voltage Range | 6.3 to 100 VDC | 160 to 450 VDC | |
| Capacitance Range | 0.47 to 22000 F | 0.47 to 470 F | |
| Capacitance Tolerance | (120Hz, 20) | 20% | |
| Leakage Current | (A) After 2 minutes with rated working voltage applied, whichever is greater | LC0.01CV or 3.0 | LC0.03CV +40 |
| Dissipation Factor (Tan) | (max, 120Hz, 20) | For capacitance 1000F, add 0.02 per another 1000F | |
| Low Temp. Characteristic | (Max Impedance Ratio) (120Hz) | For capacitance 1000F, add 0.5 per another 1000F for Z(-25)/Z(+20); add 1 per another 1000F for Z(-40)/Z(+20) | |
| Load Life Test Conditions | Duration time: 5~6.3 :2000hrs, 10 :3000hrs; Ambient temperature: +105; Applied voltage: Rated DC working voltage | After test requirements at +20: Capacitance change: within20% of initial value; Dissipation factor: 200% of initial specified value; Leakage current: initial specified value | |
| Shelf Life Test Conditions | Duration time: 1000hrs; Ambient temperature: +105; Applied voltage: None | After test requirements at +20: Same limits as Load life. Pre-treatment for measurements shall be conducted after application of DC working voltage for 30 minutes. | |
Dissipation Factor (D.F.%) vs. WV(VDC)
| WV(VDC) | D.F.(%) | WV(VDC) | D.F.(%) |
| 6.3 | 0.22 | 100 | 0.08 |
| 10 | 0.19 | 160 | 0.12 |
| 16 | 0.16 | 200 | 0.12 |
| 25 | 0.14 | 250 | 0.12 |
| 35 | 0.12 | 350 | 0.15 |
| 50 | 0.10 | 400 | 0.15 |
| 63 | 0.09 | 450 | 0.17 |
Low Temp. Characteristic (Max Impedance Ratio) vs. WV(VDC)
| WV(VDC) | Z(-25)/Z(+20) | Z(-40)/Z(+20) | WV(VDC) | Z(-25)/Z(+20) | Z(-40)/Z(+20) |
| 6.3 | 4 | 8 | 160 | 3 | 3 |
| 10 | 3 | 6 | 200 | 3 | 3 |
| 16 | 2 | 4 | 250 | 4 | 4 |
| 25 | 2 | 3 | 350 | 4 | 4 |
| 35 | 2 | 3 | 400 | 6 | 6 |
| 50 | 2 | 3 | 420 | 6 | 6 |
| 63 | 2 | 3 | 450 | 15 | |
| 100 | 2 | 3 |
2507081835_Econd-4-7uF400V10x13KM_C49304943.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible