ALUMINUM ELECTROLYTIC CAPACITORS - Econd KM Series
Econd KM Series Aluminum Electrolytic Capacitors are designed for high-performance applications. They are utilized in communication equipment, switching power supplies, and industrial measuring instruments. These capacitors offer a load life of 2000-3000 hours at 105 and are RoHS compliant.
Product Attributes
- Brand: Econd
- Series: KM
- Certifications: RoHS Compliant, JIS C-5141, JIS C-5102
Technical Specifications
| Item | Performance Characteristics | Range 1 (-40~+105) | Range 2 (-25~+105) |
|---|---|---|---|
| Operating Temp. Range | -40~+105 | -25~+105 | |
| Rated Voltage Range | 6.3 to 100 VDC | 160 to 450 VDC | |
| Capacitance Range | 0.47 to 22000 F | 0.47 to 470 F | |
| Capacitance Tolerance | (120Hz, 20) | 20% | |
| Leakage Current | (After 2 minutes with rated working voltage applied) | LC0.01CV or 3.0 (A) | LC0.03CV +40 (A) |
| Dissipation Factor (Tan) | (max, 120Hz, 20) | For capacitance 1000F, add 0.02 per another 1000F | |
| D.F.(%) for W.V(VDC) 6.3 to 100 | 0.22 (6.3V), 0.19 (10V), 0.16 (16V), 0.14 (25V), 0.12 (35V), 0.10 (50V), 0.09 (63V), 0.08 (100V) | ||
| D.F.(%) for W.V(VDC) 160 to 450 | 0.12 (160V), 0.12 (200V), 0.12 (250V), 0.15 (350V), 0.15 (400V), 0.17 (450V) | ||
| Low Temp. Characteristic (Max Impedance Ratio) | (120Hz) | For capacitance 1000F, add 0.5 per anther 1000F for Z(-25)/Z(+20); add 1 per anther 1000F for Z(-40)/Z(+20) | |
| Z(-25)/Z(+20) for W.V(VDC) 6.3 to 100 | 4 (6.3V), 3 (10V), 2 (16V), 2 (25V), 2 (35V), 2 (50V), 2 (63V), 2 (100V) | ||
| Z(-40)/Z(+20) for W.V(VDC) 6.3 to 100 | 8 (6.3V), 6 (10V), 4 (16V), 3 (25V), 3 (35V), 3 (50V), 3 (63V), 3 (100V) | ||
| Z(-25)/Z(+20) for W.V(VDC) 160 to 450 | 3 (160V), 3 (200V), 4 (250V), 4 (350V), 6 (400V), 6 (420V), 15 (450V) | ||
| Load Life Test Conditions | Duration: 2000hrs (5~6.3), 3000hrs (10) | Ambient Temp: +105, Applied Voltage: Rated DC working voltage | |
| Load Life Test Requirements (at +20) | Capacitance Change: within20% of initial; Dissipation Factor: 200% of initial specified; Leakage Current: initial specified | ||
| Shelf Life Test Conditions | Duration: 1000hrs | Ambient Temp: +105, Applied Voltage: None | |
| Shelf Life Test Requirements (at +20) | Pre-treatment: DC working voltage applied for 30 minutes | Same limits as Load life | |