Product Overview
Econd KM Series Aluminum Electrolytic Capacitors are designed for reliable performance in demanding applications. Featuring a load life of 2000-3000 hours at 105, these capacitors are suitable for communication equipment, switching power supplies, and industrial measuring instruments. They comply with RoHS environmental requirements.
Product Attributes
- Brand: Econd
- Certifications: RoHS Compliant, JIS C-5141, JIS C-5102
Technical Specifications
| Item | Performance Characteristics | Range 1 (-40~+105) | Range 2 (-25~+105) |
| Operating Temp. Range | -40~+105 | -25~+105 | |
| Rated Voltage Range | VDC | 6.3 to 100 | 160 to 450 |
| Capacitance Range | F | 0.47 to 22000 | 0.47 to 470 |
| Capacitance Tolerance | (120Hz, 20) | 20% | |
| Leakage Current (LC) | (A) After 2 min. with rated voltage | LC0.01CV or 3.0 (whichever is greater) | |
| Leakage Current (LC) | (A) After 2 min. with rated voltage | LC0.03CV +40 (whichever is greater) | |
| Dissipation Factor (Tan) | (max, 120Hz, 20) | For capacitance 1000F, add 0.02 per another 1000F | |
| Dissipation Factor (D.F.) | (%) at 120Hz, 20 | W.V(VDC): 6.3 to 100 D.F(%): 0.22 to 0.09 | W.V(VDC): 100 to 450 D.F(%): 0.08 to 0.17 |
| Low Temp. Characteristic | (Max Impedance Ratio) (120Hz) | For capacitance 1000F, add 0.5 per 1000F for Z(-25)/Z(+20), add 1 per 1000F for Z(-40)/Z(+20) | |
| Low Temp. Characteristic | Z(-25)/Z(+20) | W.V(VDC): 6.3 to 100 Ratio: 4 to 2 | W.V(VDC): 160 to 450 Ratio: 3 to 15 |
| Low Temp. Characteristic | Z(-40)/Z(+20) | W.V(VDC): 6.3 to 100 Ratio: 8 to 3 | W.V(VDC): 160 to 450 Ratio: 4 to 15 |
| Load Life Test Conditions | Duration | 5~6.3: 2000hrs, 10: 3000hrs | |
| Load Life Test Conditions | Ambient Temp. | +105 | |
| Load Life Test Conditions | Applied Voltage | Rated DC working voltage | |
| Load Life After Test Requirements | Capacitance Change | Within 20% of initial value | |
| Load Life After Test Requirements | Dissipation Factor | 200% of initial specified value | |
| Load Life After Test Requirements | Leakage Current | initial specified value | |
| Shelf Life Test Conditions | Duration | 1000hrs | |
| Shelf Life Test Conditions | Ambient Temp. | +105 | |
| Shelf Life Test Conditions | Applied Voltage | None | |
| Shelf Life After Test Requirements | Pre-treatment | Apply DC working voltage for 30 minutes at +25 before measurement | |
| Shelf Life After Test Requirements | Limits | Same limits as Load life | |