Specifications
Lifetime:
2000hrs@105℃
Operating Temperature:
-40℃~+105℃
Capacitance:
1000uF
Height - Seated (Max):
25mm
Pin Spacing:
5mm
Voltage Rating:
50V
Diameter:
13mm
Ripple Current:
1.25A@120Hz
Tolerance:
±20%
Mfr. Part #:
1000uF50V13x25KM
Package:
Through Hole,D13xL25mm
Key Attributes
Model Number: 1000uF50V13x25KM
Product Description

ALUMINUM ELECTROLYTIC CAPACITORS

Econd KM Series Aluminum Electrolytic Capacitors are designed for demanding applications in communication equipment, switching power supplies, and industrial measuring instruments. These capacitors offer a load life of 2000-3000 hours at 105 and comply with RoHS environmental requirements.

Product Attributes

  • Brand: Econd
  • Series: KM
  • Certifications: RoHS Compliant, JIS C-5141, JIS C-5102

Technical Specifications

Item Performance Characteristics Range 1 Range 2
Operating Temp. Range -40~+105 -25~+105
Rated Voltage Range 6.3 to 100 VDC 160 to 450 VDC
Capacitance Range 0.47 to 22000 F 0.47 to 470 F
Capacitance Tolerance (120Hz, 20) 20%
Leakage Current (After 2 minutes with rated working voltage applied) LC0.01CV or 3.0 (A) LC0.03CV +40 (A)
Dissipation Factor(Tan) (max, 120Hz, 20) For capacitance 1000F, add 0.02 per another 1000F
Low Temp. Characteristic (Max Impedance Ratio) (120Hz) For capacitance 1000F, add 0.5 per another 1000F for Z(-25)/Z(+20); add 1 per another 1000F for Z(-40)/Z(+20)
Load Life Test Conditions Duration time: 5~6.3 :2000hrs, 10 :3000hrs; Ambient temperature: +105; Applied voltage: Rated DC working voltage After test requirements at +20: Capacitance change: within20% of initial; Dissipation factor: 200% of initial specified; Leakage current: initial specified value
Shelf Life Test Conditions Duration time: 1000hrs; Ambient temperature: +105; Applied voltage: None After test requirements at +20: Same limits as Load life. Pre-treatment for measurements shall be conducted after application of DC working voltage for 30 minutes.

Dissipation Factor (D.F. %) vs. Working Voltage (W.V. VDC)

W.V.(VDC) 6.3 10 16 25 35 50 63 100 160 200 250 350 400 450
D.F.(%) 0.22 0.19 0.16 0.14 0.12 0.10 0.09 0.08 0.12 0.12 0.12 0.15 0.15 0.17

Low Temperature Characteristic (Max Impedance Ratio) vs. Working Voltage (W.V. VDC)

W.V.(VDC) 6.3 10 16 25 35 50 63 100 160 200 250 350 400 420 450
Z(-25)/Z(+20) 4 3 2 2 2 2 2 2 3 3 4 4 6 6 15
Z(-40)/Z(+20) 8 6 4 3 3 3 3 3 3 3 3 3 3 3