quality aluminum electrolytic capacitor Econd 68uF400V16x25KM designed for communication power supply applications factory
<
quality aluminum electrolytic capacitor Econd 68uF400V16x25KM designed for communication power supply applications factory
>
Specifications
Lifetime:
2000hrs@105℃
Operating Temperature:
-25℃~+105℃
Capacitance:
68uF
Height - Seated (Max):
25mm
Pin Spacing:
7.5mm
Voltage Rating:
400V
Diameter:
16mm
Equivalent Series Resistance(ESR):
Tolerance:
±20%
Ripple Current:
410mA@120HZ
Mfr. Part #:
68uF400V16x25KM
Package:
Through Hole,D16xL25mm
Key Attributes
Model Number: 68uF400V16x25KM
Product Description

ALUMINUM ELECTROLYTIC CAPACITORS

Econd KM Series Aluminum Electrolytic Capacitors are designed for reliable performance in demanding applications. These capacitors are utilized in communication equipment, switching power supplies, and industrial measuring instruments. They offer a load life of 2000-3000 hours at 105 and are RoHS compliant, meeting environmental requirements.

Product Attributes

  • Brand: Econd
  • Series: KM
  • Certifications: RoHS Compliant, JIS C-5141, JIS C-5102

Technical Specifications

Item Performance Characteristics
Operating Temp. Range -40~+105 / -25~+105
Rated Voltage Range 6.3 to 100 VDC / 160 to 450 VDC
Capacitance Range 0.47 to 22000 F / 0.47 to 470 F
Capacitance Tolerance 20% (120Hz, 20)
Leakage Current LC0.01CV or 3.0 (A) (After 2 minutes with rated working voltage applied, whichever is greater) / LC0.03CV +40 (A) (After 2 minutes with rated working voltage applied)
Dissipation Factor (Tan) (max, 120Hz, 20) For capacitance 1000F, add 0.02 per another 1000F. D.F values provided for various W.V(VDC).
Low Temp. Characteristic (Max Impedance Ratio) (120Hz) For capacitance 1000F, add 0.5 per another 1000F for Z(-25)/Z(+20) and add 1 per another 1000F for Z(-40)/Z(+20). Impedance ratio values provided for various W.V(VDC).
Load Life Test Conditions Duration: 2000hrs (5~6.3), 3000hrs (10). Ambient temp: +105. Applied voltage: Rated DC working voltage.
Load Life Test Requirements (at +20) Capacitance change: within 20% of initial value. Dissipation factor: 200% of initial specified value. Leakage current: initial specified value.
Shelf Life Test Conditions Duration: 1000hrs. Ambient temp: +105. Applied voltage: None.
Shelf Life Test Requirements (at +20) Same limits as Load life. Pre-treatment: DC working voltage applied for 30 minutes before measurement.