Online Service

Online Service

Contact Person
+86 13528435210
quality aluminum electrolytic capacitor Econd 33uF400V13x20KM for communication and industrial power supply factory
<
quality aluminum electrolytic capacitor Econd 33uF400V13x20KM for communication and industrial power supply factory
>
Specifications
Lifetime:
2000hrs@105℃
Operating Temperature:
-25℃~+105℃
Capacitance:
33uF
Height - Seated (Max):
20mm
Pin Spacing:
5mm
Voltage Rating:
400V
Diameter:
13mm
Equivalent Series Resistance(ESR):
750mΩ
Tolerance:
±20%
Ripple Current:
210mA@120Hz
Mfr. Part #:
33uF400V13x20KM
Package:
Through Hole,D13xL20mm
Key Attributes
Model Number: 33uF400V13x20KM
Product Description

Product Overview

Econd KM Series Aluminum Electrolytic Capacitors are designed for demanding applications in communication equipment, switching power supplies, and industrial measuring instruments. These capacitors offer a load life of 2000-3000 hours at 105 and comply with RoHS environmental standards.

Product Attributes

  • Brand: Econd
  • Origin: ELECTRONICS CO., LTD.
  • Certifications: RoHS Compliant, JIS C-5141, JIS C-5102

Technical Specifications

ItemPerformance Characteristics
Operating Temp. Range-40~+105 / -25~+105
Rated Voltage Range6.3 to 100 VDC / 160 to 450 VDC
Capacitance Range0.47 to 22000 F / 0.47 to 470 F
Capacitance Tolerance20% (120Hz, 20)
Leakage Current (LC)LC0.01CV or 3.0 (A) (after 2 min, rated voltage) / LC0.03CV +40 (A) (after 2 min, rated voltage)
Dissipation Factor (Tan) (max, 120Hz, 20)For capacitance >1000F, add 0.02 per another 1000F. Specific values provided for different W.V(VDC).
Low Temp. Characteristic (Max Impedance Ratio) (120Hz)For capacitance >1000F, add 0.5 per another 1000F for Z(-25)/Z(+20) and add 1 per another 1000F for Z(-40)/Z(+20). Specific values provided for different W.V(VDC).
Load Life Test ConditionsDuration: 2000hrs (5~6.3), 3000hrs (10). Ambient Temp: +105. Applied Voltage: Rated DC working voltage.
Load Life After Test Requirements (+20)Capacitance change: within 20% of initial. Dissipation factor: 200% of initial specified. Leakage current: initial specified.
Shelf Life Test ConditionsDuration: 1000hrs. Ambient Temp: +105. Applied Voltage: None.
Shelf Life After Test Requirements (+20)Same limits as Load life. Pre-treatment: DC working voltage for 30 minutes.