Product Overview
Econd KM Series Aluminum Electrolytic Capacitors are designed for demanding applications in communication equipment, switching power supplies, and industrial measuring instruments. These capacitors offer a load life of 2000-3000 hours at 105 and comply with RoHS environmental requirements.
Product Attributes
- Brand: Econd
- Series: KM
- Certifications: RoHS Compliant, JIS C-5141, JIS C-5102
Technical Specifications
| Item | Performance Characteristics | Range 1 | Range 2 |
| Operating Temp. Range | -40~+105 | -25~+105 | |
| Rated Voltage Range | 6.3 to 100 VDC | 160 to 450 VDC | |
| Capacitance Range | 0.47 to 22000 F | 0.47 to 470 F | |
| Capacitance Tolerance | (120Hz, 20) | 20% | |
| Leakage Current | LC0.01CV or 3.0 (A) (After 2 minutes with rated working voltage applied) | ||
| LC0.03CV +40 (A) (After 2 minutes with rated working voltage applied) | |||
| Item | W.V(VDC) | D.F(%) (max, 120Hz, 20) | ||||||
| Dissipation Factor (Tan) | 6.3 | 10 | 16 | 25 | 35 | 50 | 63 | 100 |
| 0.22 | 0.19 | 0.16 | 0.14 | 0.12 | 0.10 | 0.09 | ||
| 160 | 200 | 250 | 350 | 400 | 450 | |||
| 0.12 | 0.12 | 0.12 | 0.15 | 0.15 | 0.17 | |||
| Low Temp. Characteristic (Max Impedance Ratio) (120Hz) | W.V(VDC) | Z(-25)/Z(+20) | ||||||
| 6.3 | 10 | 16 | 25 | 35 | 50 | 63 | 100 | |
| 4 | 3 | 2 | 2 | 2 | 2 | 2 | 2 | |
| 160 | 200 | 250 | 350 | 400 | 420 | 450 | ||
| 3 | 3 | 4 | 4 | 6 | 6 | 15 | ||
| Z(-40)/Z(+20) | ||||||||
| 6.3 | 10 | 16 | 25 | 35 | 50 | 63 | 100 | |
| 8 | 6 | 4 | 3 | 3 | 3 | 3 | 3 | |
| 160 | 200 | 250 | 350 | 400 | 420 | 450 | ||
| 6 | 6 | 8 | 8 | 10 | 10 | 20 | ||
| Test Conditions | Requirements |
| Load Life Test conditions | Duration: 5~6.3: 2000hrs, 10: 3000hrs; Ambient temp: +105; Applied voltage: Rated DC working voltage |
| After test requirements at +20 | Capacitance change: within 20% of initial; Dissipation factor: 200% of initial specified; Leakage current: initial specified |
| Shelf Life Test conditions | Duration: 1000hrs; Ambient temp: +105; Applied voltage: None |
| After test requirements at +20 | Same limits as Load life. Pre-treatment: DC working voltage for 30 minutes. |
2507081835_Econd-33uF450V16x25KM_C49304985.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible