Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Metal dust core power inductor COILMX MS0650-470M designed for high current rating and low resistance performance factory
<
quality Metal dust core power inductor COILMX MS0650-470M designed for high current rating and low resistance performance factory
>
Specifications
Current - Saturation (Isat):
2.8A
Mfr. Part #:
MS0650-470M
Package:
SMD,7.2x6.6mm
Key Attributes
Model Number: MS0650-470M
Product Description

Product Overview

The MS0650-470M is a unibody power inductor designed for high-current applications. It features a metal dust core for high performance and ultra-high current rating, with super low resistance. This inductor is ROHS compliant and suitable for use up to 1MHz. Typical applications include low-profile, high-current power supplies, battery-powered devices, DC/DC converters in distributed power systems, and DC/DC converters for field-programmable gate arrays.

Product Attributes

  • Brand: SHENZHEN MOTTO TECHNOLOGY Co., Ltd
  • Model Number: MS0650-470M
  • Certifications: IATF16949 / ISO9001 / ISO14000
  • Compliance: ROHS compliant
  • Core Material: Metal dust core
  • Marking: "470" on top of the body

Technical Specifications

Parameter Specification Condition Test Instrument
Inductance (L) 47.0H 20% 100KHz / 1.0V MICROTEST 6377
DC Resistance (DCR) 290 m MAX At 25 TH2512A
Saturation Current (I sat) 2.8A TYP L0A * 70% @ 100KHz / 1.0V MICROTEST 6377 + 6220
RMS Current (I rms) 2.0A TYP T 40 @ 100KHz / 1.0V MICROTEST 6377 + 6220
Operating Temperature Range -55 ~ +125
Frequency Range Up to 1MHz

Product Dimensions (Unit: mm)

Dimension Value
A 7.15 0.35
B 6.6 0.2
C 5.0 Max
D 3.0 0.5
E 1.7 0.3

Reliability Testing

Item Specification and Requirement Test Method
Solderability Test Terminals area must have 95% min solder coverage Solder heat proof: Preheating: 16010 for 90 seconds; Retention time: 2455 for 20.5 seconds
Vibration Test Inductance change: Within5% Without mechanical damage Frequency: (10Hz to 55Hz to 10Hz) in 60 seconds as a period; Time: 2 hours in each of 3 mutual perpendicular directions; Amplitude: 1.5 mm Max
Shock Test Inductance change: Within5% Without mechanical damage Peak value: 100G; Duration of pulse: 11ms; 3 times in each positive and negative direction of 3 mutual perpendicular directions
Thermal Shock Inductance change: Within5% Without mechanical damage 100 cycles: (-552, 303 min) -> Room temp 5 min -> (+1252, 303 min) -> Room temp 5 min; Recovery: 48+4/-0 hours under standard conditions
High Temperature Life Test Inductance change: Within5% Without mechanical damage Environment: 852; Applied current: Rated current; Duration: 1000+4/-0 hours
Humidity Resistance Inductance change: Within5% Without mechanical damage Environment: 602, Humidity: 90~95%; Applied current: Rated current; Duration: 1000+4/-0 hours
Low Temperature Life Test Inductance change: Within5% Without mechanical damage Store temperature: -552 for 1000+4/-0 hours
High Temperature Storage Test Inductance change: Within5% Without mechanical damage Store temperature: +1252 for 1000+4/-0 hours

Packaging Information

Packaging Type Dimensions (mm) Quantity
Tape Packaging (W) 16.00 0.30 -
Reel Dimensions (A) 330.0 2.0 -
Carton Quantity - 9000 PCS (1 Outer Box)

2409272301_COILMX-MS0650-470M_C18199500.pdf