Specifications
Lifetime:
2000hrs@105℃
Capacitance:
22uF
Height - Seated (Max):
20mm
Pin Spacing:
7.5mm
Voltage Rating:
400V
Diameter:
16mm
Equivalent Series Resistance(ESR):
-
Tolerance:
±20%
Ripple Current:
-
Mfr. Part #:
KM226M400K20RR0VH2FP0
Package:
Through Hole,D16xL20mm
Key Attributes
Model Number: KM226M400K20RR0VH2FP0
Product Description

Aluminum Electrolytic Capacitors - KM Series

The KM Series Aluminum Electrolytic Capacitors are designed for reliable performance with a high operating temperature of 105 and a life expectancy of 1000 to 2000 hours. These standard capacitors offer a wide operating temperature range and are suitable for various applications where stable electrical characteristics are required.

Product Attributes

  • Brand: Cheng Xing ()
  • Product Name: Aluminum Electrolytic Capacitor
  • Series: KM Series
  • Origin: Dongguan, China
  • Material: Aluminum Electrolytic
  • Certifications: Not specified in the provided text.

Technical Specifications

Item Performance Characteristics Details
Operating Temperature Range -40 ~ +105 (Standard), -25 ~ +105
Rated Working Voltage Range 6.3 ~ 250V (Standard), 350~ 450V
Nominal Capacitance Range 0.1 ~ 33000F
Capacitance Tolerance 20% (120Hz, +20)
Leakage Current L0.01CV or 3(A) / l0.03cv+40(A) (Whichever is greater, measured after 2 minutes at rated voltage, +20)
Dissipation Factor (tan ) (max) at 120Hz, +20 Varies by voltage (e.g., 0.26 for 6.3V, 0.08 for 100V). Add 0.02 per 1000F for capacitance > 1000F.
Low Temperature Characteristics (120Hz) Z-25/Z+20, Z-40/Z+20 Varies by voltage (e.g., Z-25/Z+20: 5 for 6.3V, 2 for 100V; Z-40/Z+20: 10 for 6.3V, 3 for 100V).
High Temperature Loading (Load Life) 1000Hrs (D6.3), 2000Hrs (D8) at 105. Cap. change: 20% of initial. tan : 200% of initial. LC: initial specified value.
Shelf Life (No Load) 1000 Hrs at 105. Cap. change: 20% of initial. tan : 200% of initial. LC: initial specified value.
Ripple Current Correction Factors Frequency Multipliers Factors for different frequencies (50, 120, 500, 1k, 10k~ Hz) and voltage/capacitance ranges.
Standards JIS- C-5101-4 (IEC 60384)
Dimensions (D x L mm) & Ripple Current (mA/rms at 120Hz, 105) Extensive table listing various capacitance and voltage ratings with corresponding dimensions and ripple current values. (e.g., 10F / 6.3V: 5*11mm, 35mA; 1000F / 100V: 10*17mm, 617mA; 4.7F / 400V: 8*12mm, 40mA)

Usage Precautions

Circuit Design: Use within rated performance, avoid high temperature, overcurrent, overvoltage, reverse/AC voltage, and rapid charge/discharge. Ensure isolation between capacitor terminals and circuit. Select capacitors with a lifespan comparable to the machine. Consider special requirements with R&D. Avoid contact with water, salt water, oil, or environments with harmful gases, direct sunlight, ozone, UV, or radiation. Ensure vibration and shock are within specified limits. Ensure correct polarity and spacing for PCB mounting. Avoid placing heat-generating components near capacitors. For multi-capacitor connections, ensure current/voltage balancing.

Component Installation: Do not allow terminals to short circuit. Do not use dropped or deformed capacitors. Ensure PCB hole spacing matches capacitor leads. Leave space above the safety vent. Avoid placing other components or wiring above the vent. Avoid other wiring near the capacitor on the PCB. Ensure the mechanical force of automatic insertion machines is not excessive.

Soldering: Prevent solder from adhering to areas other than terminals. Follow specified soldering temperature, time, and number of cycles. Do not immerse the capacitor body in solder. Avoid other products falling onto the capacitor during soldering.

Assembly Usage: Do not allow capacitor terminals to directly contact each other or cause short circuits. Confirm the installation environment is free from water, oil, condensation, harmful gases, direct sunlight, ozone, UV, radiation, excessive vibration, or shock.

Maintenance Check: Regular checks, including visual inspection and performance testing, are required for industrial capacitors.

Accidental Situations: If the safety vent opens during assembly, cut off power. Keep face away from vent due to high-temperature gas release. Flush eyes with water if gas enters, wash skin with soap if electrolyte contacts it, and do not ingest electrolyte.

Fumigation Treatment: Exercise caution with halide-based fumigation (e.g., potassium bromide) for overseas export, as it may cause corrosion. Ensure fumigant does not directly contact products and allow for thorough drying.

Storage Conditions: Store indoors at 5-30 with humidity below 75%. Do not store in environments prohibited for use.

Disposal: Puncture or crush and incinerate, or hand over to specialized recycling personnel.