Aluminum Electrolytic Capacitors - KM Series
The KM Series Aluminum Electrolytic Capacitors are designed for reliable performance with a high-temperature rating of 105 and a life expectancy of 1000 to 2000 hours. These standard capacitors offer a wide operating temperature range and are suitable for various applications requiring stable electrical characteristics.
Product Attributes
- Brand: Cheng Xing ()
- Origin: Dongguan, China
- Series: KM Series
- Product Type: Aluminum Electrolytic Capacitor
- Material: Aluminum Electrolytic
Technical Specifications
| Item | Performance Characteristics | Details |
|---|---|---|
| Operating Temperature Range | -40 ~ +105 / -25 ~ +105 | |
| Rated Working Voltage Range | 6.3 ~250V / 350~ 450V | |
| Nominal Capacitance Range | 0.1 ~ 33000F | |
| Capacitance Tolerance | 20%(120Hz,+20) | |
| Leakage Current | L0.01CV or 3(A), l0.03cv+40(A) (Whichever is greater, measured after 2 minutes application of rated working voltage at +20) | |
| tan (max) at 120Hz, +20 | 0.26 (6.3V) to 0.08 (100V); 0.20 to 0.24 (160V-450V) | |
| Low Temperature Characteristics (120Hz) | Z-25/Z+20 | 5 (6.3V) to 2 (100V); 3 to 15 (160V-450V) |
| Low Temperature Characteristics (120Hz) | Z-40/Z+20 | 10 (6.3V) to 3 (100V); 3 to 6 (160V-450V) |
| Load Life | 1000Hrs (D6.3), 2000Hrs (D8) at 105 | Capacitance Change: 20%; tan : 200% of initial; LC: initial |
| Shelf Life | 1000 Hrs at 105 (No Load) | Capacitance Change: 20%; tan : 200% of initial; LC: initial |
| Ripple Current & Frequency Multipliers | Rate Voltage(V) / Freq(Hz) | Multipliers for 50Hz, 120Hz, 500Hz, 1kHz, 10kHz~ |
| Standards | JIS-C-5101-4 (IEC 60384) |
Standard Ratings (DxL(mm); Ripple Current: mA/rms at 120Hz,105)
| Voltage(Code) | Cap.(F) | DxL | R.C | DxL | R.C | DxL | R.C | DxL | R.C | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 6.3V | 4.7 | 5*11 | 26 | 5*11 | 35 | 5*11 | 38 | 22 | 5*11 | 44 | ||
| 5.0 | 5*11 | 59 | 5*11 | 54 | 5*11 | 57 | ||||||
| 10V | 4.7 | 5*11 | 26 | 5*11 | 35 | 5*11 | 38 | 22 | 5*11 | 44 | ||
| 10 | 5*11 | 59 | 5*11 | 54 | 5*11 | 57 | ||||||
| 16V | 4.7 | 5*11 | 26 | 5*11 | 35 | 5*11 | 38 | 22 | 5*11 | 44 | ||
| 10 | 5*11 | 59 | 5*11 | 54 | 5*11 | 57 | ||||||
| 25V | 4.7 | 5*11 | 26 | 5*11 | 35 | 5*11 | 38 | 22 | 5*11 | 44 | ||
| 10 | 5*11 | 59 | 5*11 | 54 | 5*11 | 57 | ||||||
| 35V | 0.47 | 5*11 | 7 | 5*11 | 10 | 1 | 5*11 | 13 | 5*11 | 16 | ||
| 1 | 5*11 | 10 | 5*11 | 13 | 5*11 | 16 | ||||||
| 50V | 0.47 | 5*11 | 7 | 5*11 | 10 | 1 | 5*11 | 13 | 5*11 | 16 | ||
| 1 | 5*11 | 10 | 5*11 | 13 | 5*11 | 16 | ||||||
| 63V | 0.47 | 5*11 | 7 | 5*11 | 10 | 1 | 5*11 | 13 | 5*11 | 16 | ||
| 1 | 5*11 | 10 | 5*11 | 13 | 5*11 | 16 | ||||||
| 100V | 0.47 | 5*11 | 7 | 5*11 | 10 | 1 | 5*11 | 13 | 5*11 | 16 | ||
| 1 | 5*11 | 10 | 5*11 | 13 | 5*11 | 16 | ||||||
| 160V | 0.47 | 6.3*12 | 8 | 1 | 6.3*12 | 17 | 2.2 | 6.3*12 | 27 | 3.3 | 6.3*12 | 30 |
| 200V | 0.47 | 6.3*12 | 8 | 1 | 6.3*12 | 17 | 2.2 | 6.3*12 | 27 | 3.3 | 6.3*12 | 30 |
| 220V | 0.47 | 6.3*12 | 8 | 1 | 6.3*12 | 17 | 2.2 | 6.3*12 | 27 | 3.3 | 6.3*12 | 30 |
| 250V | 0.47 | 6.3*12 | 8 | 1 | 6.3*12 | 17 | 2.2 | 6.3*12 | 27 | 3.3 | 6.3*12 | 30 |
| 350V | 0.47 | 6.3*12 | 8 | 1 | 6.3*12 | 18 | 6.3*12 | 19 | 6.3*12 | 15 | ||
| 400V | 0.47 | 6.3*12 | 8 | 1 | 6.3*12 | 18 | 6.3*12 | 19 | 6.3*12 | 15 | ||
| 420V | 0.47 | 6.3*12 | 8 | 1 | 6.3*12 | 18 | 6.3*12 | 19 | 6.3*12 | 15 | ||
| 450V | 0.47 | 6.3*12 | 8 | 1 | 6.3*12 | 18 | 6.3*12 | 19 | 6.3*12 | 15 |
Usage Precautions
Circuit Design: Use within rated performance, avoid high temperature, overcurrent, overvoltage, reverse voltage, and rapid charge/discharge. Ensure capacitors match machine lifespan. Isolate terminals and casings. Use appropriate insulation. Avoid direct contact with water, salt, oil, or harmful gases. Protect from sunlight, ozone, UV, and radiation. Ensure vibration and shock are within limits. Ensure correct polarity and spacing for mounting. Avoid placing heat-generating components near capacitors.
Component Installation: Do not short terminals. Ensure proper polarity. Avoid dropping or using deformed capacitors. Ensure terminal spacing matches PCB holes. Use appropriate force for automatic insertion machines.
Soldering: Avoid solder adhering to non-terminal areas. Follow specified temperature, time, and number of cycles. Do not immerse the capacitor body in solder. Prevent other products from contacting the capacitor during soldering.
Assembly Usage: Do not allow terminals to touch directly or cause short circuits. Ensure the environment is free from water, oil, harmful gases, and radiation. Avoid excessive vibration and shock.
Maintenance: Regular inspections, including visual checks and performance testing, are required for industrial capacitors.
Accidents: In case of capacitor safety vent activation, disconnect power immediately. Avoid close proximity to the vent due to high-temperature gas release. Flush eyes with water if exposed to vent gas. Do not ingest electrolyte. Wash skin with soap if electrolyte contact occurs.
Fumigation Treatment: Be cautious with halide-based fumigation (e.g., potassium bromide) for overseas export, as it may cause corrosion. Ensure fumigant does not directly contact products and allow for thorough drying.
Storage Conditions: Store indoors at 5-30 with humidity below 75%. Avoid storage in environments prohibited during assembly and use.
Disposal: Puncture or crush and incinerate, or hand over to specialized recyclers.