Aluminum Electrolytic Capacitors - KM Series
The KM Series Aluminum Electrolytic Capacitors are designed for reliable performance in a wide operating temperature range of -40 to +105. They offer a nominal capacitance range from 0.1 to 33000F and a rated working voltage from 6.3V to 450V. These capacitors are suitable for various applications requiring long life (1000-2000 hours) and stable electrical characteristics.
Product Attributes
- Brand: Cheng Xing ()
- Customer Name: Lichuang ()
- Origin: Dongguan, Guangdong, China
- Series: KM Series
- Material: Aluminum Electrolytic
- Certifications: Not specified
Technical Specifications
| Item | Performance Characteristics | Details |
|---|---|---|
| Operating Temperature Range | -40 ~ +105 | -25 ~ +105 |
| Rated Working Voltage Range | 6.3 ~ 250V (for -40~+105), 350~ 450V (for -25~+105) | |
| Nominal Capacitance Range | 0.1 ~ 33000F | |
| Capacitance Tolerance | 20% (120Hz, +20) | |
| Leakage Current | L0.01CV or 3(A), l0.03cv+40(A) (Whichever is greater, measured after 2 minutes at rated voltage, +20) | |
| Dissipation Factor (tan ) max. (120Hz, +20) | 0.08 to 0.26 (Varies with voltage) | |
| Low Temperature Characteristics (120Hz) | Z-25/Z+20: 2 to 10; Z-40/Z+20: 3 to 10 (Varies with voltage) | |
| Load Life | 1000Hrs (D6.3 | 2000Hrs (D8 |
| Shelf Life | 1000 Hrs (at 105) | |
| Ripple Current Multipliers | Factors for Frequency and Voltage (Refer to datasheet for details) | |
| Standards | JIS- C-5101-4 (IEC 60384) | |
Standard Ratings (DxL(mm); Ripple Current(mA/rms at 120Hz,105))
| Voltage(Code) | Cap.(F) | DxL | R.C | DxL | R.C | DxL | R.C | DxL | R.C | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 6.3V | 4.7 | 5*11 | 26 | 5*11 | 35 | 5*11 | 38 | |||||
| 10 | 5*11 | 35 | 5*11 | 38 | 5*11 | 44 | ||||||
| 22 | 5*11 | 54 | 5*11 | 57 | 5*11 | 54 | ||||||
| 10V | 4.7 | 5*11 | 26 | 5*11 | 35 | 5*11 | 38 | |||||
| 10 | 5*11 | 35 | 5*11 | 38 | 5*11 | 44 | ||||||
| 22 | 5*11 | 54 | 5*11 | 57 | 5*11 | 54 | ||||||
| 16V | 4.7 | 5*11 | 26 | 5*11 | 35 | 5*11 | 38 | |||||
| 10 | 5*11 | 35 | 5*11 | 38 | 5*11 | 44 | ||||||
| 22 | 5*11 | 54 | 5*11 | 57 | 5*11 | 54 | ||||||
| 25V | 4.7 | 5*11 | 26 | 5*11 | 35 | 5*11 | 38 | |||||
| 10 | 5*11 | 35 | 5*11 | 38 | 5*11 | 44 | ||||||
| 22 | 5*11 | 54 | 5*11 | 57 | 5*11 | 54 | ||||||
| 35V | 0.47 | 5*11 | 7 | 5*11 | 10 | 1 | 5*11 | 13 | 5*11 | 16 | ||
| 1 | 5*11 | 10 | 5*11 | 13 | 5*11 | 16 | 5*11 | 20 | ||||
| 2.2 | 5*11 | 20 | 5*11 | 23 | 5*11 | 26 | 5*11 | 30 | ||||
| 50V | 0.47 | 5*11 | 7 | 5*11 | 10 | 1 | 5*11 | 13 | 5*11 | 16 | ||
| 1 | 5*11 | 10 | 5*11 | 13 | 5*11 | 16 | 5*11 | 20 | ||||
| 2.2 | 5*11 | 20 | 5*11 | 23 | 5*11 | 26 | 5*11 | 30 | ||||
| 63V | 0.47 | 5*11 | 7 | 5*11 | 10 | 1 | 5*11 | 13 | 5*11 | 16 | ||
| 1 | 5*11 | 10 | 5*11 | 13 | 5*11 | 16 | 5*11 | 20 | ||||
| 2.2 | 5*11 | 20 | 5*11 | 23 | 5*11 | 26 | 5*11 | 30 | ||||
| 100V | 0.47 | 5*11 | 7 | 5*11 | 10 | 1 | 5*11 | 13 | 5*11 | 16 | ||
| 1 | 5*11 | 10 | 5*11 | 13 | 5*11 | 16 | 5*11 | 20 | ||||
| 2.2 | 5*11 | 20 | 5*11 | 23 | 5*11 | 26 | 5*11 | 30 | ||||
| 160V | 0.47 | 6.3*12 | 8 | 1 | 6.3*12 | 17 | 2.2 | 6.3*12 | 27 | 3.3 | 6.3*12 | 30 |
| 1 | 6.3*12 | 17 | 2.2 | 6.3*12 | 27 | 3.3 | 6.3*12 | 30 | 4.7 | 6.3*12 | 41 | |
| 2.2 | 6.3*12 | 27 | 3.3 | 6.3*12 | 30 | 4.7 | 6.3*12 | 41 | 10 | 8*12 | 60 | |
| 200V | 0.47 | 6.3*12 | 8 | 1 | 6.3*12 | 17 | 2.2 | 6.3*12 | 27 | 3.3 | 6.3*12 | 30 |
| 1 | 6.3*12 | 17 | 2.2 | 6.3*12 | 27 | 3.3 | 6.3*12 | 30 | 4.7 | 6.3*12 | 41 | |
| 2.2 | 6.3*12 | 27 | 3.3 | 6.3*12 | 30 | 4.7 | 6.3*12 | 41 | 10 | 8*12 | 60 | |
| 220V | 0.47 | 6.3*12 | 8 | 1 | 6.3*12 | 17 | 2.2 | 6.3*12 | 27 | 3.3 | 6.3*12 | 30 |
| 1 | 6.3*12 | 17 | 2.2 | 6.3*12 | 27 | 3.3 | 6.3*12 | 30 | 4.7 | 6.3*12 | 41 | |
| 2.2 | 6.3*12 | 27 | 3.3 | 6.3*12 | 30 | 4.7 | 6.3*12 | 41 | 10 | 8*12 | 60 | |
| 250V | 0.47 | 6.3*12 | 8 | 1 | 6.3*12 | 17 | 2.2 | 6.3*12 | 27 | 3.3 | 6.3*12 | 30 |
| 1 | 6.3*12 | 17 | 2.2 | 6.3*12 | 27 | 3.3 | 6.3*12 | 30 | 4.7 | 6.3*12 | 41 | |
| 2.2 | 6.3*12 | 27 | 3.3 | 6.3*12 | 30 | 4.7 | 6.3*12 | 41 | 10 | 8*12 | 60 | |
| 350V | 0.47 | 6.3*12 | 8 | 1 | 6.3*12 | 18 | 2.2 | 6.3*12 | 29 | 3.3 | 8*12 | 35 |
| 1 | 6.3*12 | 18 | 2.2 | 6.3*12 | 30 | 3.3 | 8*12 | 35 | 4.7 | 8*12 | 40 | |
| 2.2 | 6.3*12 | 30 | 3.3 | 8*12 | 35 | 4.7 | 8*12 | 40 | 10 | 10*17 | 78 | |
| 400V | 0.47 | 6.3*12 | 8 | 1 | 6.3*12 | 18 | 2.2 | 6.3*12 | 29 | 3.3 | 8*12 | 35 |
| 1 | 6.3*12 | 18 | 2.2 | 6.3*12 | 30 | 3.3 | 8*12 | 35 | 4.7 | 8*12 | 40 | |
| 2.2 | 6.3*12 | 30 | 3.3 | 8*12 | 35 | 4.7 | 8*12 | 40 | 10 | 10*17 | 78 | |
| 420V | 0.47 | 6.3*12 | 8 | 1 | 6.3*12 | 19 | 2.2 | 6.3*12 | 29 | 3.3 | 8*12 | 35 |
| 1 | 6.3*12 | 19 | 2.2 | 6.3*12 | 29 | 3.3 | 8*12 | 35 | 4.7 | 10*17 | 52 | |
| 2.2 | 6.3*12 | 29 | 3.3 | 8*12 | 35 | 4.7 | 10*17 | 52 | 10 | 13*25 | 124 | |
| 450V | 0.47 | 6.3*12 | 15 | 1 | 6.3*12 | 15 | 2.2 | 6.3*12 | 24 | 3.3 | 8*12 | 29 |
| 1 | 6.3*12 | 15 | 2.2 | 6.3*12 | 24 | 3.3 | 8*12 | 29 | 4.7 | 10*17 | 42 | |
| 2.2 | 6.3*12 | 24 | 3.3 | 8*12 | 29 | 4.7 | 10*17 | 42 | 10 | 13*25 | 84 |
Usage Precautions
Circuit Design: Use within rated performance, avoid high temperature, overcurrent, overvoltage, reverse/AC voltage, and rapid charge/discharge. Select capacitors with a lifespan comparable to the machine. Ensure isolation between capacitor terminals and circuit. Avoid using in environments with water, salt water, oil, condensation, or harmful gases. Protect from direct sunlight, ozone, UV, and radiation. Ensure vibration and shock conditions are within specified limits. For installation, ensure correct polarity, space for the safety valve, and avoid placing heat-generating components nearby. For parallel/series connections, ensure current/voltage equalization.
Component Installation: Do not let terminals directly contact. Avoid short circuits. Do not use dropped or deformed capacitors. Ensure PCB hole spacing matches capacitor lead spacing. Do not immerse the capacitor body in solder. Use appropriate soldering conditions (temperature, time, frequency). Avoid solder adhering to areas other than terminals.
Assembly & Use: Do not let terminals directly contact. Avoid short circuits. Do not use dropped or deformed capacitors. Ensure PCB hole spacing matches capacitor lead spacing. Do not immerse the capacitor body in solder. Use appropriate soldering conditions (temperature, time, frequency). Avoid solder adhering to areas other than terminals.
Maintenance: Regular checks including visual inspection and performance testing are required for industrial capacitors.
Accidental Situations: If the safety valve opens, cut off power. Keep face away from the vent due to high-temperature gas. Flush eyes with water if gas enters, wash skin with soap if electrolyte spills.
Fumigation Treatment: Be cautious with halogen-based fumigation (e.g., potassium bromide) for overseas export, as it can cause corrosion. Ensure fumigant does not directly contact products and allow for thorough drying.
Storage Conditions: Store indoors at 5-30 with humidity below 75%. Avoid environments prohibited during assembly and use.
Disposal: Puncture or crush and incinerate, or hand over to specialized recyclers.
2410121312_Chengx-KM105M400F12RR0VH2FP0_C46092.pdf