Online Service

Online Service

Contact Person
+86 136 6733 2386
quality KS Series Aluminum Electrolytic Capacitor Chengx KS685M050C07RR0VH2FP0 Rated Voltage 6.3 to 50 Volts factory
<
quality KS Series Aluminum Electrolytic Capacitor Chengx KS685M050C07RR0VH2FP0 Rated Voltage 6.3 to 50 Volts factory
>
Specifications
Operating Temperature:
-40℃~+105℃
Lifetime:
1000hrs@105℃
Capacitance:
6.8uF
Height - Seated (Max):
7mm
Voltage Rating:
50V
Pin Spacing:
1.5mm
Diameter:
4mm
Equivalent Series Resistance(ESR):
-
Tolerance:
±20%
Ripple Current:
-
Mfr. Part #:
KS685M050C07RR0VH2FP0
Package:
Through Hole,D4xL7mm
Key Attributes
Model Number: KS685M050C07RR0VH2FP0
Product Description

Product Overview

The KS Series Aluminum Electrolytic Capacitors from Dongguan Shi Cheng Xing Electronics Co., Ltd. are designed for use in electronic equipment. They offer a high operating temperature of 105 and a lifespan of 1000 hours. Key features include a compact size with a height of 7mm and standard performance characteristics suitable for various applications.

Product Attributes

  • Brand: Cheng Xing ()
  • Origin: Dongguan, China
  • Material: Aluminum Electrolytic
  • Series: KS Series
  • Certifications: JIS C-5101 (IEC 60384)

Technical Specifications

Item Performance Characteristics Value
Operating Temperature Range -40 ~ +105
Rated Working Voltage Range 6.3 ~ 50V
Nominal Capacitance Range 0.1 ~ 220F
Capacitance Tolerance 20%(120Hz,+20)
Leakage Current L0.01CV or 3(A) (measured after 2 minutes at +20)
Dissipation Factor (tan ) See table below
Low Temperature Characteristics (120Hz) See table below
Load Life 1000Hrs at 105 (Cap. change within 20%, tan 200% of initial, LC within specified value)
Shelf Life 1000 Hrs at 105 (Cap. change within 20%, tan 200% of initial, LC initial specified value)
Ripple Current & Frequency Multipliers See table below
Mechanical Characteristics: Lead strength : See table below

Dissipation Factor (tan ) at 120Hz, +20

Working Voltage (V) 6.3 10 16 25 35 50
tan (max) 0.24 0.21 0.18 0.15 0.13 0.12

Low Temperature Characteristics (120Hz) Z-25/Z+20 and Z-40/Z+20

Working Voltage (V) 6.3 10 16 25 35 50
Z-25/Z+20 4 2 2 2 2 2
Z-40/Z+20 8 6 4 3 3 3

Ripple Current & Frequency Multipliers

Freq(Hz) / Cap(F) 47 68CAP470
50 0.75 0.80
120 1.00 1.00
300 1.35 1.23
1k 1.57 1.34
10k~ 2.00 1.50

Mechanical Characteristics: Lead strength

Terminal Type d (mm) Load (Kgf) / Load (Kg)
Wire lead terminal 0.35d0.5 0.51
Wire lead terminal 0.5d0.8 1.0
Wire lead terminal 0.8d1.25 2.0
Snap-in terminal d (mm) Load (Kg)
Snap-in terminal 0.35d0.5 2.0

Standard Ratings (D x L(mm); Ripple Current: mA/rms at 120Hz,105)

Voltage(Code) Cap.(F) 6.3V 10V 16V 25V 35V 50V
Case Size Ripple Current Case Size Ripple Current Case Size Ripple Current Case Size Ripple Current Case Size Ripple Current Case Size Ripple Current
0.1 4*7 1.0
0.22 4*7 2.3
0.33 4*7 3.5
0.47 4*7 5.0
1 4*7 10 4*7 10 4*7 10 4*7 10 4*7 10 4*7 10
2.2 4*7 19 4*7 19 4*7 19
3.3 4*7 24 4*7 24 4*7 24
4.7 4*7 24 5*7 29 5*7 29
10 4*7 38 5*7 45 5*7 50 5*7 55 6.3*7 67 6.3*7 67
22 4*7 37 4*7 40 5*7 50 5*7 60 6.3*7 83 6.3*7 95
33 4*7 44 5*7 50 5*7 60 6.3*7 67 6.3*7 95 8*7 135
47 5*7 67 6.3*7 83 6.3*7 92 6.3*7 95 8*7 135 8*7 158
100 5*7 67 6.3*7 83 6.3*7 92 6.3*7 95 8*7 135 8*7 158
220 6.3*7 112 8*7 140 8*7 135 8*7 158

Usage Precautions

1. Circuit Design: Use within rated performance, avoid high temperature, overcurrent, overvoltage, reverse voltage, frequent charge/discharge. Select capacitors with lifespan matching machine life. Ensure isolation between capacitor terminals and circuit. Use with caution in environments with water, salt water, oil, condensation, harmful gases, direct sunlight, ozone, UV, or radiation. Avoid vibration and shock exceeding specifications. Ensure correct polarity and spacing for mounting. Avoid placing heat-generating components near capacitors.

2. Component Installation: Do not allow terminals to directly contact. Do not let conductive substances cause short circuits. Ensure proper installation location, avoiding other wiring or components on the circuit board. For double-sided PCBs, avoid unnecessary holes. Ensure current and voltage balance in parallel or series connections.

3. Assembly & Use: Avoid terminal contact and short circuits. Do not use capacitors that have been dropped or deformed. Ensure correct polarity and spacing. Do not immerse the capacitor body in solder. Ensure solder does not adhere to areas other than terminals. Follow specified welding conditions (temperature, time, number of times). Avoid other products falling on the capacitor during welding.

4. Maintenance: Regular inspection of capacitors in industrial use is required, including visual checks and performance testing.

5. Accidental Situations: If the capacitor's safety vent opens during assembly, cut off the main power or unplug the power. If the vent activates, hot gas exceeding 100 will be ejected; avoid direct exposure to the face and eyes. If electrolyte contacts skin, wash with soap. If it enters eyes, rinse immediately with water. Do not taste the electrolyte.

6. Fumigation Treatment: When exporting products containing capacitors overseas, be cautious of fumigation with halides like potassium bromide, as it may cause corrosion. Fumigant should not directly contact products, and thorough drying is necessary.

7. Storage Conditions: Store indoors at temperatures of 5-30 and humidity below 75%. Do not store in environments or conditions prohibited during assembly and use.

8. Disposal: Puncturing or crushing and then incinerating capacitors is one disposal method. Alternatively, hand over to specialized waste recycling personnel.


2410311335_Chengx-KS685M050C07RR0VH2FP0_C45667.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max