Online Service

Online Service

Contact Person
+86 136 6733 2386
quality safety capacitor CHAMPION SMQP224K310XXD2B15150 featuring climatic category 40 110 56 and passive flammability class B rating factory
<
quality safety capacitor CHAMPION SMQP224K310XXD2B15150 featuring climatic category 40 110 56 and passive flammability class B rating factory
>
Specifications
Capacitance:
220nF
Operating Temperature:
-40℃~+110℃
Ratings:
X2
Tolerance:
±10%
Voltage(AC):
310V
safety certification:
UL;VDE;ENEC;CQC;KC
Mfr. Part #:
SMQP224K310XXD2B15150
Package:
Through Hole,P=15mm
Key Attributes
Model Number: SMQP224K310XXD2B15150
Product Description

Product Overview

This document details the technical specifications and characteristics of the MPX-X2 series capacitors manufactured by GUANGDONG CHAMPION ELECTRONIC TECHNOLOGY CO., LTD. These capacitors are designed for safety standard applications and are built with a metallized polypropylene film and metal plating (zinc-aluminum) for reliable performance.

Product Attributes

  • Brand: CHAMPION
  • Origin: China
  • Material: Metallized Polypropylene Film
  • Certifications: UL, ENEC, IEC, GB/T, KC, CQC

Technical Specifications

ParameterSpecification
Reference StandardGB/T 6346.14 (IEC 60384-14)
Standard Capacity0.001~4.7F
Capacity Error Grade5% (J), 10% (K)
Rated Voltage (AC)250V, 275V, 300V, 310V, 330V, 350V
Climatic Category40/110/56
Operating Temperature Range-40~110
Passive Flammability ClassB
Voltage Proof (Between Terminals)UN4.3 DC, 60s
Voltage Proof (Between Terminal and Case)UN x 200+1500Vac, 60sec
Dissipation Factor10 x 10 at 1kHz, (1Vrms Max. at 20)
Insulation Resistance (CR 0.33F)15000M
Insulation Resistance (CR > 0.33F)IR x CR 5000s (100Vdc, 60sec / 20)
Manufacturer Code DescriptionSMQP 475 K 275 XF13 B 28 150 (Example breakdown: Capacity, Error Grade, Rated Voltage, Case Code, Feet Style, Lead Pitch, Lead Length)
Marking ExplanationManufacturer Logo, Product Type (MPX), Product Material, Standard Capacity Value, Capacity Error Grade, Rated Voltage, Climate Category, Fire Retardant Grade
Safety Standard Certifications (MPX-X2)UL 60384-14 (E477525), EN60384-14:2013 (ENEC-01273-A3), IEC 60384-14:2013 (40044148), GB/T 6346.14-2015 (CQC16001141991), KC 60384-14(2015-09) / KC 60384-1(2015-09) (SU03097-...)
Detection Criteria - Withstand Voltage (Between Leads)Shall be no abnormality (Rated voltage 430% DC test for 1 minute)
Detection Criteria - Withstand Voltage (Between Lead and Enclosure)Shall be no abnormality (200% rated voltage +1500VAC test for 1min)
Detection Criteria - Dissipation Factor0.001 (0.1%) Max (Voltage: 1Vrms, Frequency: 1KHz, Temperature: 20)
Detection Criteria - Insulation ResistanceCR 0.33F, IR 15000M; CR > 0.33F, IR x CR 5000s (Voltage: 10015VDC, Time: 1min, Temperature: 20)
Detection Criteria - Lead StrengthNo line break, no visible damage (Tensile: 10N10% for D0.8mm, 20N10% for D1.0mm; Bending: 5N10% for D0.8mm, 10N10% for D1.0mm)
Detection Criteria - Resistance to Soldering HeatNo visible damage; Capacity change rate 5% (Soldering temp: 2605, Time: 50.5sec)
Detection Criteria - Solderability(Soldering temp: 2355, Time: 20.5sec)
Detection Criteria - Rapid Change of TemperatureLower limit: -40, Upper limit: 110, Cycles: 5, Duration: 30 min
Detection Criteria - Climate Category (Test Db)No visible damage; Capacity change rate 5%; No permanent breakdown or arcing; Insulation resistance 50% of applicable value; DF 0.008 (10KHz, CN1F); 0.005 (1KHz, CN>1F)
Detection Criteria - Dry HeatUpper limit: 110, Duration: 16Hrs
Detection Criteria - Damp Heat, Cyclic (Test Db)First cycle, Remaining cycle
Detection Criteria - ColdLower limit: -40, Duration: 2Hrs
Detection Criteria - Damp Heat, Steady StateTemperature: 40C 2C, Humidity: 933%, Duration: 56 days
Detection Criteria - Durability125% rated voltage, hourly rise to 1000VAC 0.1 seconds, 110 1000 hours
Detection Criteria - Charging and DischargingTesting voltage: 2UN(DC), Number of replication: 10000 Times, Charge/discharge time: 1 sec/times
Detection Criteria - Passive Flammability TestCapacitor shall not continue to burn for more than 10 seconds after leaving flame, and drops shall not ignite cotton paper. (Test duration based on volume V: 20s for 2501750)
Storage Conditions and DurationStore in a clean, ventilated, dry warehouse, away from heat sources and direct sunlight. Not to be stored with chemical reagents, acids, or harmful gases. Temperature: 5~35, Relative Humidity: 75%. Storage duration: One year.

Dimensions

Nominal Capacity (F)Width (mm)Height (mm)Thickness (mm)
0.0011094
0.00151094
0.00221094
0.00271094
0.00331094
0.00391094
0.00471094
0.00561094
0.00681094
0.00821094
0.011094
0.0151094
0.0221094
0.0271094
0.0331094
0.0391094
0.0471094
0.0561094
0.0681094
0.0821094
0.11094
0.151094
0.221094
0.271094
0.331094
0.391094
0.471094
0.561094
0.681094
0.821094
11094
1.210126
1.510126
1.810126
210126
2.210126
2.510126
2.710126
310126
3.310126
3.510115
3.910126
410115
4.710126
32413016

2506251635_CHAMPION-SMQP224K310XXD2B15150_C49247341.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max