CapXon FH Series Aluminum Electrolytic Capacitors
Product Overview
The CapXon FH Series is a high-ripple current, 105C rated aluminum electrolytic capacitor designed for demanding applications. Featuring THT (Through-Hole Technology) mounting, these capacitors offer excellent endurance from 4,000 to 10,000 hours, low impedance, and a wide capacitance range up to 18000F. They are suitable for low-voltage applications requiring reliable performance under elevated temperatures and high ripple current conditions.
Product Attributes
- Brand: CapXon
- Series: FH Series
- Type: Aluminum Electrolytic Capacitor
- Mounting: THT (Through-Hole Technology)
- Temperature Rating: 105C
Technical Specifications
Key Features
- High Ripple Current
- Endurance: 105C, 4,000 hours up to 10,000 hours
- Low Impedance
- Wide Capacitance Range: 6.8F to 18000F
- Low Voltage Version Available
General Specifications
| Item | Performance Characteristics |
|---|---|
| Operating Temperature Range | -40 ~ +105C |
| Rated Voltage Range (VR) | 6.3 ~ 100V DC |
| Surge Voltage (VS) | VS = 1.15VR |
| Capacitance Range (CR) | 6.8 ~ 18000F |
| Capacitance Tolerance (C) | 20% (120Hz, 20C) |
| Leakage Current (ILEAK) | 0.01CRVR or 3A (whichever is greater) after 2 minutes (20C, VR applied) |
| Dissipation Factor (tan) at 120Hz, 20C | See table below |
| Low Temperature Characteristics at 120Hz (Z ratio max.) | See table below |
| Lifetime Test Endurance | 105C (VR & IR applied) |
| Shelf Life | 105C (VR = 0) for 1,000 hours |
Dissipation Factor (tan) % at 120Hz, 20C
| VR (V DC) | tan (%) |
|---|---|
| 6.3 | 22 |
| 10 | 19 |
| 16 | 16 |
| 25 | 14 |
| 35 | 12 |
| 50 | 10 |
| 63 | 9 |
| 100 | 8 |
Note: For CR > 1000F, add 2% per every multiple 1000F of rated capacitance value.
Low Temperature Characteristics at 120Hz (Z-ratio max.)
| VR (V DC) | Z-25C/Z+20C | Z-40C/Z+20C |
|---|---|---|
| 6.3 | 4 | 8 |
| 10 | 3 | 6 |
| 16 | 2 | 4 |
| 25 | 2 | 3 |
| 35 | 2 | 3 |
| 50 | 2 | 3 |
| 63 | 2 | 3 |
| 100 | 2 | 3 |
Note: For capacitance > 1000F, add 0.5 to Z-25C/Z+20C and add 1 to Z-40C/Z+20C for every multiple 1000F of rated capacitance value.
Endurance Test Conditions
105C (VR & IR applied)
- 4,000 hours: D 6.3 mm; 6.3 ~ 10V
- 5,000 hours: D 6.3 mm; 16 ~ 100V
- 6,000 hours: D = 8 & 10 mm; 6.3 ~ 10V
- 7,000 hours: D = 8 & 10 mm; 16 ~ 100V
- 8,000 hours: D 13 mm; 6.3 ~ 10V
- 10,000 hours: D 13 mm; 16 ~ 100V
During Test: C/CR 25% of initial value, tan 200% of initial specified value, ILeak initial specified value.
Shelf Life Test Conditions
105C (VR = 0)
- 1,000 hours
During Test: C/CR 25% of initial value, tan 200% of initial specified value, ILeak initial specified value.
Dimensions
| D (mm) | F (mm) | d (mm) | L (mm) for L < 20 | L (mm) for L 20 | a (mm) for D < 16 | a (mm) for D = 16 | a (mm) for D = 18 |
|---|---|---|---|---|---|---|---|
| 5 | 2 | 0.5 | 0.6 | 0.8 | 1.5 | - | - |
| 6.3 | 2.5 | 0.5 | 0.6 | 0.8 | 1.5 | - | - |
| 8 | 3.5 | 0.6 | 0.6 | 0.8 | 1.5 | - | - |
| 10 | 5 | 0.6 | 0.6 | 0.8 | 1.5 | - | - |
| 13 | 5 | 0.6 | 0.6 | 0.8 | 1.5 | - | - |
| 16 | 7.5 | 0.8 | 0.6 | 0.8 | - | 2 | - |
| 18 | 7.5 | 0.8 | 0.6 | 0.8 | - | - | 2 |
Note: Dimensions for L are based on L values. For L = 25 to 35.5, a = 1.5 for D < 16, a = 2 for D = 16, a = 1.5 for D = 18. For L < 25 and L 40, a = 1.5 for D < 16, a = 2 for D = 16, a = 1.5 for D = 18. For L = 25 to 31.5, a = 1.5 for D < 16, a = 2 for D = 16, a = 1.5 for D = 18. For L < 25 and L 35.5, a = 1.5 for D < 16, a = 2 for D = 16, a = 1.5 for D = 18.
Multiplier Kf for Ripple Current vs. Frequency
| CR (F) / Frequency (Hz) | 50/60 | 100/120 | 400 | 1k | 10k | 100k |
|---|---|---|---|---|---|---|
| CR 10 | 0.47 | 0.59 | 0.76 | 0.85 | 0.97 | 1 |
| 10 < CR 100 | 0.52 | 0.62 | 0.8 | 0.89 | 0.97 | 1 |
| 100 < CR 1000 | 0.58 | 0.72 | 0.84 | 0.9 | 0.98 | 1 |
| 1000 CR | 0.63 | 0.78 | 0.87 | 0.91 | 0.98 | 1 |
Standard Ratings (Partial List)
| VR (V) | CR (F) | D (mm) | L (mm) | Z Max. Impedance +20C, 100kHz (m) | IR Max. Ripple Current +105C, 100kHz (mA rms) | CapXon Part Number |
|---|---|---|---|---|---|---|
| 6.3 | 150 | 5 | 11 | 550 | 220 | FH151M6R3C110A |
| 6.3 | 220 | 6.3 | 11 | 260 | 300 | FH221M6R3E110A |
| 6.3 | 330 | 6.3 | 11 | 210 | 350 | FH331M6R3E110A |
| 6.3 | 470 | 8 | 11.5 | 140 | 440 | FH471M6R3F115A |
| 10 | 100 | 5 | 11 | 580 | 220 | FH101M010C110A |
| 10 | 220 | 6.3 | 11 | 230 | 350 | FH221M010E110A |
| 16 | 56 | 5 | 11 | 560 | 220 | FH560M016C110A |
| 25 | 47 | 5 | 11 | 560 | 220 | FH470M025C110A |
| 35 | 33 | 5 | 11 | 550 | 230 | FH330M035C110A |
| 50 | 22 | 5 | 11 | 650 | 220 | FH220M050C110A |
| 63 | 15 | 5 | 11 | 1800 | 65 | FH150M063C110A |
| 100 | 6.8 | 5 | 11 | 1800 | 65 | FH6R8M100C110A |
(Full standard ratings available in the original document)
Disclaimer: All product-related data is subject to change without notice. Customers are responsible for ensuring product suitability for their intended applications and performing necessary validation and reliability evaluations. Consult CapXon for lifetime estimations, failure mode considerations, or worst-case scenarios. For critical applications (aerospace, life-saving, safety-critical), consult CapXon before design-in.
For further information, please visit www.capxongroup.com or contact CapXon directly.
2410121655_CapXon-FH470M025C110A_C5129734.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible