Product Overview
The Piher PT-15 and PTC-15 are 15-mm through-hole potentiometers designed for applications requiring frequent adjustment. Featuring a shaftless design, they offer flexibility for various engagement mechanisms and can control variable outputs such as frequency, motor speed, or volume. These potentiometers boast excellent performance with up to 3% linearity, carbon or cermet resistive elements, and up to 100,000 life cycles. They are suitable for a wide range of applications including appliance program selection, thermostat adjustment, consumer electronics, and test equipment.
Product Attributes
- Brand: Piher
- Series: PT-15 / PTC-15
- Resistive Element: Carbon or Cermet
- Substrate: Polyester / Alumina
- Flammability: Self-extinguishable plastic (UL 94V-0) available (standard for PTC-15)
- Protection: IP54
- Packaging: Magazine packaging for automatic insertion available
- Certifications: ISO 14001
Technical Specifications
| Specification | PT-15 | PTC-15 |
|---|---|---|
| Taper | Lin, Log, Alog | Lin, Log, Alog |
| Range of values | Lin: 100 Rn 5M Log, Alog: 1K Rn 5M | Lin: 100 Rn 5M Log, Alog: 1K Rn 5M |
| Tolerance (100 Rn 1M) | 20% | 20% |
| Tolerance (1M < Rn 5M) | 30% | 30% |
| Max. Voltage | 250 VDC (Lin) 125 VDC (Log, Alog) | 250 VDC (Lin) 125 VDC (Log, Alog) |
| Nominal power (50C) | 0.25 W (Lin) 0.12 W (Log, Alog) | 0.25 W (Lin) 0.12 W (Log, Alog) |
| Nominal power (70C) | 0.50 W (Lin) 0.25 W (Log, Alog) | 0.50 W (Lin) 0.25 W (Log, Alog) |
| Residual resistance | 0.5% Rn (5 min.) | 0.5% Rn (5 min.) |
| Equivalent noise resistance | 3% Rn (3 min.) | 3% Rn (3 min.) |
| Operating temperature | -25C to +70C | -40C to +90C |
| Mechanical rotation angle | 265 5 | 265 5 |
| Electrical rotation angle | 240 20 | 240 20 |
| Torque | 0.5 to 2.5 Ncm (0.7 to 3.4 in-oz) | 0.5 to 2.5 Ncm (0.7 to 3.4 in-oz) |
| Rotational Stop | > 10 Ncm (>14 in-oz) | > 10 Ncm (>14 in-oz) |
| Life Cycles | Up to 100k cycles | Up to 10k cycles |
| Detents | Up to 38 | Up to 38 |
| Environmental Testing (Electrical Life) | 1.000h at 50C; 0.15W: 5% R | n/a |
| Environmental Testing (Electrical Life) | n/a | 1.000h at 70C; 0.33W: 2% R |
| Environmental Testing (Mechanical Life) | 1000 cycles at 10 to 15 cpm: 3% R (Rn < 1M) | 1000 cycles at 10 to 15 cpm: 2% R (Rn < 1M) |
| Environmental Testing (Temperature Coefficient) | -25C to +70C: 300 ppm/C (Rn < 100K) | -40C to +90C: 100 ppm/C (Rn < 100K) |
| Environmental Testing (Thermal Cycling) | 16h at 85C and 2h at -25C: 2.5% R | 16h at 90C and 2h at -40C: 2% R |
| Environmental Testing (Damp Heat) | 500h at 40C and 95% RH: 5% R | 500h at 40C and 95% RH: 2% R |
| Environmental Testing (Vibration) | 2h each plane at 10Hz - 55Hz: 2% R | 2h each plane at 10Hz - 55Hz: 2% R |
| Environmental Testing (Storage) | 6 month at 23C 2C and 50% RH: 2.5% R | 6 month at 23C 2C and 50% RH: 2% R |