Product Overview
The ARCOL HS Aluminium Housed Resistors are designed for direct heatsink mounting to achieve maximum performance, manufactured in line with MIL 18546 and IEC 115 requirements. These resistors offer high power-to-volume ratio and are wound to maximize high pulse capability. They are suitable for applications requiring robust power dissipation and are RoHS compliant. The range is available in ohmic values from R005 to 100K, with custom designs welcome. For optimal heat transfer, a heat sink compound is recommended between the resistor base and the heat sink mounting surface to prevent exceeding the maximum hot spot temperature of 200C.
Product Attributes
- Brand: ARCOL
- Origin: UK
- Material: Aluminium Housing
- Certifications: MIL 18546, IEC 115, RoHS Compliant
- Product Type: Aluminium Housed Resistors
- Non-Inductive Option: NHS Series available
Technical Specifications
| Model | MIL-R 18546 | Power rating on std. heatsink @25C (Watts) | Power rating with no heatsink @25C (Watts) | Resistance Range | Limiting element voltage (V) | Voltage proof AC Peak (V) | Voltage proof AC rms (V) | Approx weight (gms) | Typical surface rise HS mounted (C) | Standard heatsink cm | Thickness (mm) | Dimensions (mm) - A Max | Dimensions (mm) - B Max | Dimensions (mm) - C Max | Dimensions (mm) - D Max | Dimensions (mm) - E Max | Dimensions (mm) - F 0.3 | Dimensions (mm) - G 0.3 | Dimensions (mm) - H Max | Dimensions (mm) - J Max | Dimensions (mm) - K Max | Dimensions (mm) - L 0.25* | Dimensions (mm) - M Max |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| HS10 | RE | 10 | 5 | R005-10K | 160 | 1400 | 1000 | 4 | 5.8 | 415 | 1 | 16.5 | 30.0 | 8.8 | 8.5 | 15.9 | 11.3 | 12.4 | 4.5 | 2.4 | 1.8 | 2.4 | - |
| HS15 | RE | 15 | 7 | R005-10K | 265 | 1400 | 1000 | 7 | 5.1 | 415 | 1 | 21.0 | 36.5 | 11.0 | 11.2 | 19.9 | 14.3 | 15.9 | 5.5 | 2.8 | 1.8 | 2.4 | - |
| HS25 | RE | 25 | 9 | R005-36K | 550 | 3500 | 2500 | 14 | 4.2 | 535 | 1 | 28.0 | 51.0 | 14.8 | 14.2 | 27.3 | 18.3 | 19.8 | 7.7 | 5.2 | 2.6 | 3.2 | - |
| HS50 | RE | 50 | 14 | R01-86K | 1250 | 3500 | 2500 | 32 | 3.0 | 535 | 1 | 28.0 | 72.5 | 14.8 | 14.2 | 49.1 | 39.7 | 21.4 | 8.4 | 5.2 | 2.6 | 3.2 | - |
| HS75 | - | 75 | 24 | R01-50K | 1400 | 6363 | 4500 | 85 | 1.1 | 995 | 3 | 47.5 | 72.0 | 24.1 | 27.3 | 48.7 | 29.0 | 37.0 | 11.8 | 10.4 | 3.7 | 4.4 | - |
| HS100 | - | 100 | 30 | R01-70K | 1900 | 6363 | 4500 | 115 | 1.0 | 995 | 3 | 47.5 | 88.0 | 24.1 | 27.3 | 65.2 | 35.0 | 37.0 | 11.8 | 15.4 | 3.7 | 4.4 | - |
| HS150 | - | 150 | 45 | R01-100K | 2500 | 6363 | 4500 | 175 | 1.0 | 995 | 3 | 47.5 | 121.0 | 24.1 | 27.3 | 97.7 | 58.0 | 37.0 | 11.8 | 20.4 | 3.7 | 4.4 | - |
| HS200 | - | 200 | 50 | R01-50K | 1900 | 7070 | 5000 | 475 | 0.7 | 3750 | 3 | 72.5 | 145.7 | 41.8 | 45.5 | 89.7 | 70.0 | 57.2 | 20.5 | 10.4 | 5.5 | 5.1 | 103.4 |
| HS250 | - | 250 | 55 | R01-50K | 2200 | 7070 | 5000 | 600 | 0.6 | 4765 | 3 | 72.5 | 167.0 | 41.8 | 45.5 | 109.7 | 89.0 | 57.2 | 20.5 | 10.4 | 5.5 | 5.1 | 122.4 |
| HS300 | - | 300 | 60 | R01-68K | 2500 | 7070 | 5000 | 700 | 0.6 | 5780 | 3 | 72.5 | 184.4 | 41.8 | 45.5 | 127.7 | 104.0 | 59.0 | 20.5 | 12.4 | 5.5 | 6.6 | 141.4 |
Characteristics
- Tolerance (Code): Standard 5% (J) and 10% (K). Also available 1% (F), 2% (G) and 3% (H).
- Tolerance for low values: Typically R05 5%, R047 10%.
- Temperature coefficients: < 1K 100ppm Std., > 1K 25ppm Std. Lower TCRs available upon request.
- Insulation resistance (Dry): 10,000 M minimum.
- Power dissipation: Derates linearly to zero at 200C at high ambient temperatures.
- Ohmic values: From R005 to 100K depending on wattage size.
- Low inductive (NHS): Specify by adding N before HS Series code (e.g., NHS50).
- NHS ohmic value: Divide standard HS maximum value by 4.
- NHS working volts: Divide standard HS maximum working voltage by 1.414.
Terminations
The HS Range offers a variety of termination options:
- Standard Pressed Termination: Available on HS10-50, 75-150.
- 6.35mm Spade Termination (Amp style push on): Available on HS10-50, HS75-150.
- Unpressed Termination: Available on HS10-50, 75-150.
- Extended Mouldings: To increase creepage and strike distance between terminal and housing. Available on HS10-50, HS75-150, and HS200-300 (E6 using stud mounted resin disk).
- Attached Termination to Drawing: Available on HS10-50, HS75-150.
- Threaded Stud Termination: Available on HS25-50 (E3), HS75-150 (E4 or E6), HS200-300 (E6).
- Leaded Termination: Leads fitted and insulated externally after moulding. Available with standard lead lengths: HS10-50 (150mm), HS75-150 (150mm), HS200-300 (300mm). Extra length available on request.
For other special terminations, high voltage, low inductance windings, or water-cooled types (HSW600), please contact ARCOL sales.