Product Overview

The GE Critical Power FLTR100V20 Filter Module is engineered to significantly reduce conducted common-mode and differential-mode noise on the input or output lines of high-frequency switching power supplies. Designed for PC board mounting in natural convection or forced-air environments, this RoHS-compliant module provides high insertion loss across the frequency ranges regulated by the FCC and CISPR. It is optimized for use with high-frequency DC-to-DC power modules, offering a robust solution for communication and computer equipment to meet stringent international EMI requirements. The FLTR100V20 is compatible with both Pb-free and SnPb reflow environments and meets various international safety and directive standards.

Product Attributes

  • Brand: GE Critical Power
  • Model: FLTR100V20
  • RoHS Compliance: RoHS Compliant to Directive 2011/65/EU
  • Certifications: CAN/CSA C22.2 No. 60950-1-07 / UL* 60950-1, Second Edition; VDE 0805 (EN60950) Licensed; CE mark meets 73/23/EEC and 93/68/EEC directives
  • Compatibility: Compatible in Pb-free or SnPb reflow environment
  • Mounting: Printed-circuit board mountable

Technical Specifications

Parameter Symbol Min Max Unit
Input Voltage: Continuous VI 75 Vdc
Input Voltage: Transient (100 ms) VI, trans 100 Vdc
Voltage from GND to Either Input Lead (1 minute) 2500 Vdc
Operating Case Temperature Tc -40 100 C
Storage Temperature Tstg 55 125 C
Resistance per Leg R 6.6 m
Maximum Average Current (TA = 48 C, 2.0 m/s (400 lfm) air) Natural convection I max 13 A
Maximum Average Current (TA = 48 C, 2.0 m/s (400 lfm) air) Forced Air I max 20 A
Common-mode Insertion Loss (50 circuit, 500 kHz) 32 dB
Differential-mode Insertion Loss (50 circuit, 500 kHz) 36 dB
Dimensions (L x W x H) 50.8 x 40.6 x 12.7 (2.0 x 1.6 x 0.50) mm (in.)